Loading...
HomeMy WebLinkAbout2181 LOGAN AVE i INVOICE DATE DUE DATE INVOICE# TOTAL DUE /Cr11�',► 4r•% 04/27/2023 05/30/2023 2023-00011201 $80.00 I Customer#: 4431 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HY-VEE#2 715 Mulberry St 2181 LOGAN AV WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -2181 LOGAN AVE-2-15-23 FOR BILLING INQUIRY: (319)291-43231 Description J Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4431 04/27/2023 05/30/2023 2023-00011201 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo WATERLOO FIRE RESCUE �PtER�oQ INSPECTION REPORT t � 1 HY-VEE,2181 LOGAN AVE,BLDG 2181 LOGAN AVE,WATERLOO IA 50703 DETAILS Inspection Date:02/15/2023 ! Inspection Type:Annual Inspection(1Yr) Inspection Number:8039 ; Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A ! Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:A. relocate booth.Maintain a minimum of 36" clearance to exit door in dining area.B.remove storage Upper office exit path as posted FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:Provide documentation of generator engine service,load bank test,and ceiling emergency light testing with all discrepancies corrected. FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a ignition. listed disposal container.Contents of such containers shall be removed and disposed of daily. Inspector:JEFF SIEBEL-Comments:obtain approved listed oily waste container with self closing lid for all oily materials. Printed on 02/16/2023 @ 13:15 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 509.2-Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage,trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Inspector:JEFF SIEBEL-Comments:maintain a clear 36"path to fire sprinkler riser at ' all times.Remove obstructions. �- . '; r, so � FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed . for the movement of compressed gas containers,cylinders or tanks.3. Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public. Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress.4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector:JEFF SIEBEL-Comments:Secure compressed gas cylinders to wall with CHAIN:upper chiller room FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. ♦� „ .., Inspector:JEFF SIEBEL-Comments:repair broken conduit and outlet by bakery/utensil sales rack/chicken area in kitchen. 444, Printed on 02/16/2023 @ 13:15 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) i in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be II Pi: = providedin front of electrical service equipment.Where the electrical service .,, , , -fi equipment•is •wider •than 30 inches(762 mm),the minimum •working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are -t required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:Remove obstructions,maintain a minimum ` .tj. clearance of 9"on sides and 36"in front of electrical panels,and install permanent signage stating"No Storage Maintain 36"Clearance"in following areas:A.2 areas in 1 ems-- _ / back storage area B. in bakery and kitchen area. 14E1 1 FAIL 603.4.1 -Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating"ELECTRICAL ROOM"or similar approved wording.The disconnecting means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Inspector:JEFF SIEBEL-Comments: Install permanent sign stating"Electrical Room" on door to main disconnect in chiller room. FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817. Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental _ ; _ damage or physical impact.Extension cords shall be used only with portable II"IllIll111 ''� --,'t= appliances. Extension cords marked for indoor use shall not be used outdoors. "IIIIII_. i ., 1x' -,i , Inspector:JEFF SIEBEL-Comments:A. Remove extension cord, power strip and ,. portable heater by fire sprinkler riser. Install permanent heater with permit and inspections. B. remove extension cord in accounting C. Remove extension cord to Dr Pepper cooler by front entrance and install permanent power with permits and lta'' . inspections.All appliances must plug directly into a permanent outlet. Printed on 02/16/2023 @ 13:15 Page 3of5 • STATUS CODE DESCRIPTION FAIL 603.9.4-Prohibited areas. Portable,electric space heaters shall not be operated within 3 feet(914 mm)of any combustible materials. Portable,electric space heaters shall be operated only in locations for which they are listed. Inspector:JEFF SIEBEL-Comments:remove portable electric heaters:A.fire sprinkler riser area B.Scan area. FAIL 606.3.3.3-Records. Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood exhaust cleaning and fire suppression inspection reports with all discrepancies corrected.Contractor must upload online to the compliance engine. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:Replace missing ceiling tile:A.above customer service B.mailroom C.trim room(prep room) FAIL 906.5-Conspicuous location. Portable fire extinguishers shall be located in conspicuous locations where they will have ready access and be immediately available for use.These locations shall be along normal paths of travel,unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. Inspector:JEFF SIEBEL-Comments: Install fire extinguisher location sign above shelving height on column in store area in front of customer service area. Printed on 02/16/2023 @ 13:15 Page 4 of 5 STATUS CODE DESCRIPTION FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured. or areas in which visual obstruction cannot be completely avoided,means shall be provided to indicate the locations of extinguishers. Inspector:JEFF SIEBEL-Comments:remove obstructions,maintain a minimum 36" clearance to fire extinguisher in customer service. GENERAL NOTES JEFF SIEBEL-02/16/2023 @ 11:56 Annual inspection$100 JEFF SIEBEL-02/16/2023 @ 11:57 provide corrections to avoid progressive re-inspection fees beginning at$100 REINSPECTION DATE 03/08/2023 CONTACT SIGNATURE Conor Erickson Signed on:02/16/2023 @ 11:57 �C INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/16/2023 @ 11:57 QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/16/2023 @ 131 S Page 5 of 5