COMMERCIAL INSPECTION - 1515 FLAMMANG DR-3-27-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price
INSPECTION 1 $40.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE 2023 INVOICE# 83 CHARGES $50 00
14415 04/26/2023 04/05/2023
Less Prepayment $0.00
Total Due—+ $50.00
City of Waterloo
WATERLOO FIRE RESCUE `V
INSPECTION REPORT 1 t / \
GAMESTOP,1515 FLAMMANG DR,BLDG 1515 FLAMMANG DR,WATERLOO IA 50702
DETAILS
Inspection Date:03/27/2023 ! Inspection Type:Annual Inspection(1Yr) ; Inspection Number:4790 I Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL ( Other Inspectors: N/A Fee:$50.00
STATUS CODE DESCRIPTION
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments: Repair exit-egress lights:A.above main front
door. B.above back door above TV
FAIL 704.1 -Maintaining Where required when the building was originally constructed,materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.Joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in back storage area.
GENERAL NOTES
JEFF SIEBEL-03/30/2023 @ 11:55 annual inspection$50
JEFF SIEBEL-03/30/2023 @ 11:55 provide corrections to avoid progressive re-inspection fees beginning at$100
REINSPECTION DATE
04/17/2023
Printed on 03/30/2023 @ 11:56
Page 1 of 2
CONTACT SIGNATURE
Zach moran 2023 , c ‘ 72
Signed on:03/30/2023 @ 11:53
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:03/30/2023 @ 11:54
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL