Loading...
HomeMy WebLinkAbout669 S HACKETT RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE ll�Aiil -- 04/26/2023 04/05/2023 2023-00011190 $100.00 i4.1 !Ake ' i lrizilp!„..--",:+qi Customer#: 4456 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St YMCA 669 S HACKETT RIB WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 669 S HACKETT RD - 3-15-23 FOR BILLING INQUIRY: (319)291-4323 I I Total Price J [Description $100.00 REINSPECTION 1 CHARGES CUSTOMER# BILLING DATE DUE DATE INVOICE#4456 04/26/2023 04/05/2023 2023-00011190 $100.00 Less Prepayment $0.00 Total Due ---* $100.00 City of Waterloo ui knit SLt9 WATERLOO FIRE RESCUE .L1PtER,�O A INSPECTION REPORT YMCA,669 S HACKETT,BLDG 669 S HACKETT RD,WATERLOO/A 50701 DETAILS Inspection Date:03/15/2023 1 Inspection Type:Annual Inspection(1Yr) j Inspection Number:7451 ! Shift: N/A i Station: N/A Unit: N/A 1 Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A i Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. r + - 's - Inspector:JEFF SIEBEL-Comments:Remove obstructions to rear exit from child care area and back hallway. \ '/16.,.. FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:Repair egress lights:A.Men fitness plus by sinks. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair Exit/Egress Lights:A.to main office.B.Exit light from big pool to little pool.C.exit light top of kids clubhouse.D.Exit light MPRB. E.Men's locker room main door. FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:Provide documentation of testing and repair in women's locker room. Printed on 03/16/2023 @ 10:32 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 2003.7-Hazardous material Hazardous materials shall be stored in accordance with Chapter 50. storage. Inspector:JEFF SIEBEL-Comments:Remove acid storage from AHU room by spa equipment room.AHU and Spa equipment doors must remained closed at all times. FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEFF SIEBEL-Comments:provide documentation of dryer vent cleaning to the outside of the building. FAIL 704.1 -Maintaining Where required when the building was originally constructed,materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1 Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments: 1.Remove wedges do not prop doors to stairs from wellness center.2.Replace missing ceiling tiles:A.By Hannah's office.B.Janitors closet by small pool. FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments:Fire doors must completely self-close and latch:A. by front desk. B.pool equipment room C.fire doors to child care center. Printed on 03/16/2023 @ 10:32 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. Expired in 2021 GENERAL NOTES JEFF SIEBEL-03/16/2023 @ 09:38 Annual inspection$100 JEFF SIEBEL-03/16/2023 @ 09:39 Fire drills practiced monthly:Last 2/9/23 24 children. JEFF SIEBEL-03/16/2023 @ 09:39 Provide service for AED,battery dead and all pads expired. REINSPECTION DATE 04/06/2023 CONTACT SIGNATURE Adam Schweitzer l Signed on:03/16/2023 @ 10:31 S GI S Printed on 03/16/2023 @ 10:32 Page 3 of 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:03/16/2023 @ 10:31 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/16/2023 @ 10:32 Page 4 of 4