HomeMy WebLinkAbout1831 iNDEPENDENCE AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE
���►��\� 'Oita' 04/26/2023 04/05/2023 2023-00011192 $80.00
_m
. m
°terloo \o
Customer#: 3361 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
715 Mulberry St
HALF PINT SALO WATERLOO,00, lA 50703
1831 INDEPENDF .E AV
WATERLOO,IA 50707
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION - 1831 INDEPENDENCE AVE- 3-10-23 FOR BILLING INQUIRY: (319)291-4323
Total Price
L Description
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
ATE INVOICE#
CUSTOMER# BILLING DATE..., DUE D2023 202 00011192 CHARGES $80.00
3361 04/26/2023 04/05/
Less Prepayment $0.00
Total Due-* $80.00
City of Waterloo
WATERLOO FIRE RESCUE 4,,ERLo0
INSPECTION REPORT ' 4,
HALF PINT SALOON,1831 INDEPENDENCEAVE,BLDG 1831 INDEPENDENCEAVE,WATERLOO
IA S0703
DETAILS
Inspection Date:03/10/2023 Inspection Type:Annual Inspection(1Yr) ; Inspection Number:7540 Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers
conditionsOpen electrical shall be provided for all switch and electrical outlet boxes.
terminations.
Inspector:JEFF SIEBEL-Comments:install listed blanks or breakers in open slots in
electrical panel.
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings,nor shall such cords be subject to environmental
damage or physical impact.Extension cords shall be used only with portable
appliances.Extension cords marked for indoor use shall not be used outdoors.
Inspector:JEFF SIEBEL-Comments:remove extension cord from Electrical panel to TV
in back room. Install permanent power with permits and inspections.
FAIL 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be
cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3.
Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood
exhaust cleaning inspection report with all discrepancies corrected.Contractor must
upload online to the compliance engine. •
GENERAL NOTES
JEFF SIEBEL-03/13/2023 @ 09:46 annual inspection fee$80
JEFF SIEBEL-03/13/2023 @ 09:47 corrected during inspection:chained CO tanks behind bar,removed multiplug adapter
above pool table.
Printed on 03/13/2023 @ 09:50
Page 1 of 2
REINSPECTION DATE
03/30/2023
CONTACT SIGNATURE
Mike Maker
Signed on:03/13/2023 @ 09:48 / C/a
I c
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:03/13/2023 @ 09:48
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 03/13/2023 @ 09:50
Page 2 of 2