Loading...
HomeMy WebLinkAbout650 LA PORTE RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE /6-40 w, NM. 04/26/2023 04/05/2023 2023-00011197 $100.00 .. -::—.- m 4'11er14;o �o Customer#: 12606 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St CADILLAC LANES 650 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 650 LA PORTE RD 3-1-23 FOR BILLING INQUIRY: (319)291-4323 [Description I Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12606 04/26/2023 04/05/2023 2023-00011197 $100.00 Less Prepayment $0.00 Total Due --- $100.00 City of Waterloo WATERLOO FIRE RESCUE .(P4 4vtERt00 INSPECTION REPORT 1M D' CADILLAC LANES,650 LA PORTE RD,BLDG 650 LA PORTE RD,WATERLOO/A 50702 DETAILS • Inspection Date:03/01/2023 I Inspection Type:Annual Inspection(1Yr) ; Inspection Number:7725 I Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light in kitchen. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit light:A.North East exit hall B.exit light top of stairs to Fran's lab.C.from Fran's lab. • FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing ignition sources. devices and combustible materials,shall be maintained in an approved manner. Inspector:JEFF SIEBEL-Comments:remove oil container storage from within 36"of appliances.REPEAT VIOLATION. FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress.4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector:JEFF SIEBEL-Comments:Secure compressed gas cylinders with chain to avoid tip-over in sound closet for pop. FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under doors or floor coverings,or be subject to environmental or physical damage. Printed on 03/03/2023 @ 09:58 Page 1 of 3 STATUS CODE DESCRIPTION Inspector:JEFF SIEBEL-Comments:Properly mount power strip on wall or floor to the ticket ring claw machine. FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments: Remove extension cord to clock at front bar. FAIL 705.2.6-Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Inspector:JEFF SIEBEL-Comments:provide documentation of current fire door drop testing for two doors. GENERAL NOTES JEFF SIEBEL-03/01/2023 @ 15:52 annual inspection fee$100 JEFF SIEBEL-03/01/2023 @ 15:52 dryer vent cleaning by Drew Lubka 2/23 JEFF SIEBEL-03/03/2023 @ 09:57 kitchen hood fire suppression due 3/2/23 REINSPECTION DATE 03/22/2023 CONTACT SIGNATURE Mick Hackbarth Signed on:03/03/2023 @ 08:41 C 17.i/1._ ,— c. < Printed on 03/03/2023 @ 09:58 Page 2 of 3 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:03/03/2023 @ 08:41 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 03/03/2023 @ 09:58 Page 3 of 3