COMMERCIAL INSPECTION - 3040 LEVERSEE RD - 3-1-23 FOR BILLING INQUIRY: (319)291-4323
[Description Total Price
REINSPECTION 1 $100.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
7148 04/26/2023 04/05/2023 2023-00011198 $100.00
Less Prepayment $0.00
Total Due $100.00
City of Waterloo
WATERLOO FIRE RESCUE 401547,4
INSPECTION REPORT
R C'MILLET CO,3040 LEVERSEE RD,BLDG 3040 LEVERSEE RD,WATERLOO/A 50703
DETAILS
Inspection Date:03/01/2023 Inspection Type:Annual Inspection(1Yr) j Inspection Number:2943 j Shift: N/A I Station: N/A
Unit: N/A Lead Inspector:JEREMIAH VANDYKE 1 Other Inspectors: N/A j Fee:$100.00
STATUS CODE DESCRIPTION
FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination. with Sections 1008.3 and 1104.5.1.
Inspector:JEREMIAH VANDYKE-Comments:Tested and failed multiple EXIT and
EGRESS lights.Has started to replace all lights with LED throughout building.
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEREMIAH VANDYKE-Comments:Tested and failed multiple EXIT and
EGRESS lights.Has started to replace all lights with LED throughout building.
FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor
system inspection
Inspector:JEREMIAH VANDYKE-Comments:Sprinkler system must be inspected and
deficiencies corrected by licensed sprinkler contractor and inspection report
uploaded to compliance engine by servicing contractor.
FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner.Rooms
containing controls for air-conditioning systems,sprinkler risers and valves,or other
fire detection,suppression or control elements fire protection systems shall be
identified for the use of the fire department.Approved signs required to identify fire
protection system equipment and equipment location shall be constructed of
== 1 durable materials, permanently installed and readily visible.
I Inspector:JEREMIAH VANDYKE-Comments:Signage stating Fire Alarm Control Panel
&Sprinkler Riser"needed on outside door,made of durable materials.Planning on
• F placing near west door.
Printed on 03/03/2023 @ 14:23
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10.Exceptions:1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned,properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEREMIAH VANDYKE-Comments:2 fire extinguishers are past due,located
in:1.Tan building and 2.Lagun building. Must be replaced or serviced.Side note:
Extinguishers located in main building/offices are compliant/serviced Proshield in
October 2022.
FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor
testing,and maintenance
Inspector:JEREMIAH VANDYKE-Comments:Fire Alarm must be inspected and
deficiencies corrected by licensed fire alarm contractor and inspection report
uploaded to compliance engine by servicing contractor.
GENERAL NOTES
JEREMIAH VANDYKE-03/03/2023 @ 14:03 Will be moving Knox box to different location.
JEREMIAH VANDYKE-03/03/2023 @ 14:03 Re-inspection dates are automatically generated 30 days out from the initial
inspection.Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.
JEREMIAH VANDYKE-03/03/2023 @ 14:03 Re inspection fees may be assessed for subsequent re-inspections.Re-inspection fees
start at$100,then$150,and$200 for all subsequent re-inspections.-
JEREMIAH VANDYKE-03/03/2023 @ 14:04 Inspection Fee=$100.00
Printed on 03/03/2023 @ 14:23
Page 2 of 3
REINSPECTION DATE
04/02/2023
CONTACT SIGNATURE
Rex Willett Contact Refused
Refusal Reason: N/A emailed.
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on:03/03/2023 @ 14:22
QUESTIONS ABOUT YOUR INSPECTION?
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
No phone number available
Printed on 03/03/2023 @ 14:23