Loading...
HomeMy WebLinkAbout1422 FLAMMANG DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4#417111411k :.; 02/15/2023 03/20/2023 2023-00011123 $235.00 M N.A r�ww/ Customer#: 4706 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HY-VEE#3 715 Mulberry St 1422 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1422 FLAMMANG DR- 1-19-23 FOR BILLING INQUIRY: (319)291-4323 LDescription J Total Price, INSPECTION 50,000 $225.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4706 02/15/2023 03/20/2023 2023-00011123 $235.00 Less Prepayment $0.00 Total Due— $235.00 City of Waterloo WATERLOO FIRE RESCUE (t..A ‘ .4) , AD �ptER[aQ INSPECTION REPORT 0 s \ HY-VEE,1422 FLAMMANG DR,BLDG 1422 FLAMMANG DR,WATERLOO IA S0702 DETAIL )Q133C Inspection Date:01/19/2023 j Inspection Type:Annual Inspection(1Yr) I Inspection Number:7424 ( Shift: N/A I Station: N/A I Unit: N/A Lead Inspector:JEFF SIEBEL ( Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments:repair back exit door from upstairs offices areas ASAP.Must unlatch and swing to full open with less than 15#force. FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:remove storage from exit pathway to back exit lk stairs of office area.NO STORAGE allowed.REPEAT VIOLATION. r 4 Printed on 01/21/2023 @ 14:27 Page 1 of 6 STATUS CODE DESCRIPTION FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing ignition sources. devices and combustible materials,shall be maintained in an approved manner. Inspector:JEFF SIEBEL-Comments: Remove combustible materials from top of .. _ charging floor scrubber(rags)and within 36"of scrubber. s • ji. L 'a Ors °`.�'�' � �.R.� .moll'- oll' a r Printed on 01/21/2023 @ 14:27 Page 2 of 6 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service jot,- ava f '-= � equipment is wider than 30 inches(762 mm),the minimum working space shall be {: or not less than the width of the equipment.Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove storage from in front of electrical panel: A.liquor storage.B.transformer,disconnect and electric panel in grocery to go area. --_ C.Chinese Kitchen. I all W �x- NE \ 4:0403 Printed on 01/21/2023 @ 14:27 Page 3 of 6 STATUS CODE DESCRIPTION FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental opoirr,,„„ AJ damage or physical impact.Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Ak Vir Inspector:JEFF SIEBEL-Comments:remove extension cord from employee room breakroom. FAIL 603.9.4-Prohibited areas. Portable,electric space heaters shall not be operated within 3 feet(914 mm)of any combustible materials. Portable,electric space heaters shall be operated only in locations for which they are listed. Inspector:JEFF SIEBEL-Comments:remove portable electric heater in floral area. FAIL 606.3.3.3-Records. Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood fire suppression inspection report with all discrepancies corrected.currently 192 days past due.Contractor must upload online to the compliance engine. FAIL 705.2.6-Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Inspector:JEFF SIEBEL-Comments:provide current annual fire door drop test inspection reports. Reports maybe emailed to inspector. Printed on 01/21/2023 @ 14:27 Page 4 of 6 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. GENERAL NOTES JEFF SIEBEL-01/21/2023 @ 14:01 annual inspection$235 JEFF SIEBEL-01/21/2023 @ 14:04 obstructions to fire sprinkler riser and exit door in back storage area were removed during inspections. REINSPECTION DATE 02/09/2023 CONTACT SIGNATURE Dave Bowling Signed on:01/21/2023 @ 14:05 Kc,„ L;) INSPECTOR SIGNATURE JEFF SIEBEL Signed on:01/21/2023 @ 14:05 Printed on 01/21/2023 @ 14:27 Page 5 of 6 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/21/2023 @ 14:27 Page 6 of 6