Loading...
HomeMy WebLinkAbout4535 KIMBALL AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE �17)1FA 21.:; 02/15/2023 03/20/2023 2023-00011131 $80.00 41tt'rloo �o Customer#: 14295 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable TRINITY DAYCARE 715 Mulberry St 4535 KIMBALL AV WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-4535 KIMBALL AVE-1-31-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 14295 02/15/2023 03/20/2023 2023-00011131 $80.00 Less Prepayment $0.00 Total Due —* $80.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT i TRINITY PRESCHOOL,4535 KIMBALL AVE,BLDG 4535 KIMBALL AVE,WATERLOO IA 50701 4� DETAILS Inspection Date:01/31/2023 j Inspection Type:Annual Inspection(1Yr) I Inspection Number:7069 I Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A j Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:remove temporary barricades when church is occupied.(blocking exit) FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit light by parish office. FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions to electrical panel and fire alarm panel buy church office.. Maintain a minimum of 36"clearance at all times. FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEFF SIEBEL-Comments:provide documentation of dryer vent cleaning to the outside with signature and date. Printed on 02/01/2023 @ 09:00 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group I-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers GENERAL NOTES JEFF SIEBEL-02/01/2023 @ 08:55 annual inspection$80 JEFF SIEBEL-02/01/2023 @ 08:56 Deliberator requires service indicator is on.Check dates on pads as well. JEFF SIEBEL-02/01/2023 @ 08:57 Fire drills practiced monthly. Last was 12/20/22 @3:30 with 36 kids. REINSPECTION DATE 03/03/2023 CONTACT SIGNATURE Carrie Nieman E'c-i lam/Signed on:02/01/2023 @ 08:57 Printed on 02/01/2023 @ 09:00 Page 2 of 3 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/01/2023 @ 08:57 ,' QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/01/2023 @ 09:00 Page 3 of 3