Loading...
HomeMy WebLinkAbout2834 ANSBOROUGH AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE ��� 1I" 11��;1 11 ;ir,,� 02/16/2023 03/20/2023 2023-00011154 $100.00 aiMP lit 4'11e717:o �o Customer#: 20752 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HY-VEE#1 715 Mulberry St 2834 ANSBOROUGH AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -2834 ANSBOROUGH AVE-2-14-23 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price INSPECTION 2,000 HH $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 20752 02/16/2023 03/20/2023 2023-00011154 $100.00 Less Prepayment $0.00 Total Due -* $100.00 City of Waterloo WATERLOO FIRE RESCUE soTER1.°) INSPECTION REPORT I HY-VEE,2834 ANSBOROUGH AVE,BLDG 2834 ANSBOROUGH AVE,WATERLOO/A 50701 DETAILS Inspection Date:02/14/2023 ; Inspection Type:Annual Inspection(1Yr) I Inspection Number:7496 Shift: N/A I Station: N/A I Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A ; Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1010.2.5-Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1.On doors not required for egress in individual dwelling units or sleeping units.2.Where a pair of doors serves a storage or equipment room,manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware.4.Where a pair of doors serves a Group B,F or S occupancy,manually operated edge-or surface-mounted bolts are permitted on the inactive leaf provided that such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware.5.Where a pair of doors serves patient care rooms in Group 1-2 occupancies,self-latching edge-or surface-mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. Inspector:JEFF SIEBEL-Comments:REPEAT OFFENSE.PERMANETENTLY REMOVE AND REPAIR HOLES.Will initiate re-inspection fee whenever lock is in place. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:replace exit light aisle 11 dairy. Printed on 02/16/2023 @ 08:41 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks, if dislodged,do not obstruct the required means of egress.4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector:JEFF SIEBEL-Comments:Secure compressed gas cylinders to wall with chain:A.customer service area. B.upper loft area by ladder. FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions to electrical panels. REPEAT VIOLATION.maintain a minimum of 36"clearance to electrical panel and water heater at all times. FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide current service for fire extinguisher in equipment room upstairs. Printed on 02/16/2023 @ 08:41 Page 2 of 3 STATUS CODE DESCRIPTION FAIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:all extinguishers must be mounted 4"to 5'above the ground. Install extinguisher in proper place that is on floor by back storage stairs. (kitchen extinguisher replaced during inspection). GENERAL NOTES JEFF SIEBEL-02/16/2023 @ 08:28 annual inspection$100 REINSPECTION DATE 03/13/2023 CONTACT SIGNATURE Jared Lekar / Signed on:02/16/2023 @ 08:30 -c J 4/-`• r INSPECTOR SIGNATURE JEFF SIEBEL /4 Signed on:02/16/2023 @ 08:30 QUESTIONS AEOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/16/2023 @ 08:41 Page 3 of 3