Loading...
HomeMy WebLinkAbout2000 HAWTHORNE AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE /l'�,,�11, N i;,; 02/16/2023 03/20/2023 2023-00011156 $100.00 ; t`'�ji '1 to Customer#: 20795 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SAC'S NEIGHBORHOOD PUB 715 Mulberry St P.O.BOX 961 WATERLOO, IA 50703 Waterloo, IA 50704 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2000 HAWTHORNE AVE-2-8-23 FOR BILLING INQUIRY: (319)291-4323 Description 1 Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 20795 02/16/2023 03/20/2023 2023-00011156 $100.00 Less Prepayment $0.00 Total Due —± $100.00 City of Waterloo + ER WATERLOO FIRE RESCUE $ INSPECTION REPORT t S.A.C'S NEIGHBORHOOD BAR,2000 HAWTHORNEAVE,BLDG 2000 HAWTHORNEAVE, WATERLOO IA 50702 4t14106 DETAILS Inspection Date:02/08/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:9515 I Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are • required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). VIP Inspector:JEFF SIEBEL-Comments:remove obstructions to electric panel .maintain a minimum of 36"clearance.Worse on 2/8 FAIL 606.3.3.3-Records. Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood exhaust system and hood fire suppression inspection reports with all discrepancies corrected.Currently hood cleaning 56 days past due and hood fire suppression 247 days past due.contactor must upload reports online to the compliance engine. Printed on 02/12/2023 @ 10:45 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual fire extinguisher inspection service. GENERAL NOTES JEFF SIEBEL-02/12/2023 @ 10:35 re-inspection fee$100 REINSPECTION DATE 03/07/2023 CONTACT SIGNATURE Randy Soper RSigned on:02/12/2023 @ 10:42 C l G 4)24 1C INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/12/2023 @ 10:42 Printed on 02/12/2023 @ 10:45 Page 2of3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/12/2023 @ 10:45 Page 3 of 3