Loading...
HomeMy WebLinkAbout503-SOUTH ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE /1�1414b, fgt. 02/16/2023 03/20/2023 2023-00011158 $80.00 palte '161 oo ‘o Customer#: 12081 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GROUT MUSEUM 715 Mulberry St 503 SOUTH ST WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 503 SOUTH ST- 1-26-23 FOR BILLING INQUIRY: (319)291-4323 LDescription ( Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12081 02/16/2023 03/20/2023 2023-00011158 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo WATERLOO FIRE RESCUE094)) 4„,..„00 ,e‘A INSPECTION REPORT 1 z 1J GROUT MUSEUM,503 SOUTH ST,BLD6 503 SOUTH ST,WATERLOO/A 50702 DETAILS Inspection Date:01/26/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:7225 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1004.9-Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load of load. the room or space posted in a conspicuous place,near the main exit or exit access doorway from the room or space,for the intended configurations. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized agent. Inspector:JEFF SIEBEL-Comments:move occupancy sign back to banquet room from classroom FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:provide documentation of testing and repair of all emergency egress and exit lights in building including the exit light by pioneer hall door and CBS LA-2A-37 showing failed battery. FAIL 315.3.2-Means of egress. Combustible materials shall not be stored in exits or enclosures for stairways and ramps.Combustible materials in the means of egress during construction, demolition, remodeling or alterations shall comply with Section 3312.3. Inspector:JEFF SIEBEL-Comments:remove gasoline(snow blower)from exit vestibule by old fire pumper. 1 Printed on 01/27/2023 @ 12:00 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEFF SIEBEL-Comments:properly contain wires on tamper valve on fire sprinkler wet riser to labeled to old building. a • ,.4.. ' FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: Provide annual fire extinguisher service.last 2021 GENERAL NOTES JEFF SIEBEL-01/27/2023 @ 11:50 annual inspection$80 JEFF SIEBEL-01/27/2023 @ 11:55 Smoke detectors taped over in room next to wood shop was removed during inspection.Smoke detectors found to be taped over in construction area in lower level. Advised contractor must be removed every night or when not actively working in area. JEFF SIEBEL-01/27/2023 @ 11:56 Printed on 01/27/2023 @ 12:00 Page 2 of 3 Y REINSPECTION DATE 02/21/2023 CONTACT SIGNATURE Ray Shepard / Signed on:01/27/2023 @ 11:58 c._ c71 4 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:01/27/2023 @ 11:58 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/27/2023 @ 12:00 Page 3 of 3