Loading...
HomeMy WebLinkAbout3815 UNIVERSITY AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE ���,,�Ria ,; 02/16/2023 03/20/2023 2023-00011162 $80.00 OltiPIP Customer#: 12631 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DOLLAR GENERAL 715 Mulberry St 100 MISSION RIDGE WATERLOO, IA 50703 GOODLETTSVILLE, TN 37072 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3815 UNIVERSITY AVE-2-2-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price- INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12631 02/16/2023 03/20/2023 2023-00011162 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo WATERLOO FIRE RESCUE y,„Ep,.00 INSPECTION REPORT \ DOLLAR GENERAL,3815 UNIVERSITYAVE,BLDG 3815 UNIVERSITYAVE,WATERLOO/A 50701 DETAILS Inspection Date:02/02/2023 Inspection Type:Annual Inspection(1Yr) j Inspection Number:7334 I Shift: N/A I Station: N/A I Unit: N/A ; Lead Inspector:JEFF SIEBEL 1 Other Inspectors: N/A i Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit/egress above dock door. FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:JEFF SIEBEL-Comments:remove multi-plug adapter from office breakroom FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguisher in break room. GENERAL NOTES JEFF SIEBEL-02/08/2023 @ 08:39 annual inspection$80 Printed on 02/08/2023 @ 08:47 Page 1 of 2 REINSPECTION DATE 03/01/2023 CONTACT SIGNATURE corporate F Signed on:02/08/2023 @ 08:43 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/08/2023 @ 08:39 QUESTIONS ASOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/08/2023 @ 08:47 Page 2 of 2