Loading...
HomeMy WebLinkAbout306 WASINGTON ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE �141■� i.:; 02/16/2023 03/20/2023 2023-00011163 $80.00 411,1 °Iterloo �o Customer#: 21386 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SNOWDEN HOUSE 715 Mulberry St 306 WASHINGTON WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 306 WASHINGTON ST- 1-26-23 FOR BILLING INQUIRY: (319)291-4323 Description ( Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 21386 02/16/2023 03/20/2023 2023-00011163 $80.00 Less Prepayment $0.00 Total Due --> $80.00 City of Waterloo 4ptERI.DO WATERLOO FIRE RESCUEa 1_9..v1 INSPECTION REPORT j SNOWDEN HOUSE,306 WASHINGTON ST,BLDG 306 WASHINGTON ST,WATERLOO/A 50702 DETAILS Inspection Date:01/26/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number:3958 I Shift: N/A E Station: N/A I Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments:repair exit door to fire escape on second floor. Door must unlatch and swing to full open with less than 15#force.Currently door will not open at all. FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner.Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials,permanently installed and readily visible. Inspector:JEFF SIEBEL-Comments: Install permanent red sign with red letters stating "Fire Sprinkler Riser Room"near opening to fire sprinkler riser room but visible across room to fire fighters. Printed on 01/27/2023 @ 12:44 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. GENERAL NOTES JEFF SIEBEL-01/27/2023 @ 12:40 annual inspection$80 JEFF SIEBEL-01/27/2023 @ 12:41 Fire escape last inspected 12/9/19 REINSPECTION DATE 02/21/2023 CONTACT SIGNATURE Alan Sweeney Signed on:01/27/2023 @ 12:43 (L,Z) S U�✓ INSPECTOR SIGNATURE JEFF SIEBEL Signed on:01/27/2023 @ 12:43 Printed on 01/27/2023 @ 12:44 Page 2of3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/27/2023 @ 12:44 Page 3 of 3