COMMERCIAL INSPECTION - 1905 SCHUKEI RD - 1-18-23 FOR BILLING INQUIRY: (319)291-4323
[Description Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24041 02/16/2023 03/20/2023 2023-00011165 $80.00
Less Prepayment $0.00
Total Due — $80.00
City of Waterloo
WATERLOO FIRE RESCUE
INSPECTION REPORT
LUCKY NAIL,1905 SCHUKEI RD,BLDG 1905 SCHUKEI RD,WATERLOO IA 50702
DETAILS
Inspection Date:01/18/2023 I Inspection Type:Annual Inspection(1Yr) j Inspection Number:9500 I Shift: N/A I Station: N/A I
Unit: N/A I Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1 01 0.1 -Doors. Means Doors in the means of egress shall comply with the requirements of Sections
1010.1.1 through 1010.3.4.Exterior exit doors shall meet also comply with the
requirements of this section.Doors serving a Section 1022.2.Gates in the means of
egress shall comply with the requirements of Sections 1010.4 and 1010.4.1.Turnstiles
in the means of egress system shall meet comply with the requirements of this
fl section and Section 1022.2.Doors Sections 1010.5 through 1010.5.4.Doors,gates
and turnstiles provided for egress purposes in numbers greater than required by
this code shall meet comply with the requirements of this section.Doors in the
Means means of egress doors shall be readily distinguishable from the adjacent
construction and finishes such that the doors are easily recognizable as doors.
Mirrors or similar reflecting materials shall not be used on means of egress doors.
_ is Means of egress doors shall not be concealed by curtains,drapes,decorations or
similar materials.
Inspector:JEFF SIEBEL-Comments:required exit doors must not be disguised.
Remove screen assembly from the back exit door.
FAIL 1010.2.9-Panic and fire exit Swinging doors serving a Group H occupancy and swinging doors serving rooms or
hardware. spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be
provided with a latch or lock other than panic hardware or fire exit hardware.
Exceptions: 1.A main exit of a Group A occupancy shall be permitted to have locking
devices in accordance with Section 1010.2.4,Item 2 3.2.Doors provided with panic
- hardware or fire exit hardware and serving a Group A or E occupancy shall be
permitted to be electrically locked in accordance with Section 1010.2.12 or 1010.2.11.
3. Exit access doors serving occupied exterior areas shall be permitted to be locked in
accordance with Section 1010.2.4, Item 8.4.Courtrooms shall be permitted to be
A' locked in accordance with Section 1010.2.13, Item 3.Electrical rooms with equipment
rated 1,200 amperes or more and over 6 feet(1829 mm)wide,and that contain
overcurrent devices,switching devices or control devices with exit or exit access
doors,shall be equipped with panic hardware or fire exit hardware.The doors shall
swing in the direction of egress travel.
} z. Inspector:JEFF SIEBEL-Comments:remove sheetrock screws from panic hardware..
Device must be operable at all times.
n
1f (
Printed on 01/20/2023 @ 10:13
Page 1 of 5
STATUS CODE DESCRIPTION
FAIL 102.4-Application of building The design and construction of new structures shall comply with the International
code. Building Code,and any alterations,additions,changes in use or changes in
structures required by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
Inspector:JEFF SIEBEL-Comments:Obtain final inspections for all trades and building
permits.
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
F >i, s ffi Inspector:JEFF SIEBEL-Comments:remove chair from exit path in front of exit door.
I t
11';-1,14:!II''''i
FAIL 2403.3-Storage,use and The storage,use and handling of flammable and combustible liquids shall be in
handling of flammable and accordance with this section and Chapter 57.
combustible liquids.
Inspector:JEFF SIEBEL-Comments:purchase an approved flammable liquids storage
cabinet to store all cases of acetone. Doors must be self-closing.
- --"At-Ns:— .0044(
f ,s, J.,-: 0,,,,,, _
, .
Printed on 01/20/2023 @ 10:13
Page 2 of 5
STATUS CODE DESCRIPTION
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings,nor shall such cords be subject to environmental
damage or physical impact.Extension cords shall be used only with portable
`4 appliances. Extension cords marked for indoor use shall not be used outdoors.
;.-;:- y " Inspector:JEFF SIEBEL-Comments:Remove all extension cords and power taps
'--- -`""- currently connected to and powering permanent salon chairs.All power cords must
�. - be accessible and not encased in structure.Install permanent wall outlets with
' ''‘.'-''',,- -,- _ _ proper •permits and inspections.
x
�s .1
\\'::. _ 41011P.
Fi „;:• ; i, ,,,..ii., , cr,:, I,
Ali.
€ { =c i_lid S i,7 r /
-�_ "7 to 4tl L
FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a
clothes dryer shall be maintained in accordance with the manufacturer's operating
instructions to prevent the accumulation of lint or debris that prevents the exhaust
of air and products of combustion.
Inspector:JEFF SIEBEL-Comments: Provide documentation of dryer vent cleaning to
the outside of the building with signature and date.
Printed on 01/20/2023 @ 10:13
Page 3 of 5
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations:1.In new
and existing Group A,B,E,F,H,I,M,R-1,R-2,R-4 and S occupancies.Exceptions:1.In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where
forklift, powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10-
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3.Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation, use and inspection of extinguishers.3.5. Inspections of vehicle-
mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; I-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored,used or dispensed.4.On each floor of
structures under construction,except Group R-3 occupancies,in accordance with
Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special-
hazard areas,including but not limited to laboratories,computer rooms and
generator rooms,where required by the fire code official. Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector:JEFF SIEBEL-Comments:properly mount currently serviced fire
extinguisher in accessible location 4'to 5'above the floor at front of business.
GENERAL NOTES
JEFF SIEBEL-01/20/2023 @ 10:12 Provide all corrections by 1/29/23 to avoid progressive re-inspection fees beginning at
$100
JEFF SIEBEL-01/20/2023 @ 09:36 annual inspection$80
REINSPECTION DATE
01/30/2023
Printed on 01/20/2023 @ 10:13
Page 4 of 5
CONTACT SIGNATURE
Tommy Nguyen \� /�
Signed on:01/20/2023 @ 09:25 U C
y
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:01/20/2023 @ 09:25
QUESTIONS AMOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 01/20/2023 @ 10:13
Page 5 of 5