Loading...
HomeMy WebLinkAbout1625 SYCAMORE ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE /P'�1ir■\,'�•; 02/16/2023 03/20/2023 2023-00011166 $50.00 °terloo Customer#: 24042 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MINTEYS STOP AND SHOP 715 Mulberry St 1625 SYCAMORE ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1625 SYCAMORE ST-2-8-23 FOR BILLING INQUIRY: (319)291-4323 l Description I Total Price INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24042 02/16/2023 03/20/2023 2023-00011166 $50.00 Less Prepayment $0.00 Total Due —> $50.00 City of Waterloo \oe WATERLOO FIRE RESCUE �pSER��O INSPECTION REPORT t MINTEYS STOP AND SHOP,1625 SYCAMORE ST,BLDG 1625 SYCAMORE ST-STE WHITE GARAGE IN ALLEY,WATERLOO/A 50703 DETAILS Inspection Date:02/08/2023 ( Inspection Type:Annual Inspection(1Yr) j Inspection Number:9626 j Shift: N/A Station: N/A I Unit: N/A j Lead Inspector:JEFF SIEBEL 1 Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEFF SIEBEL-Comments:Contact City of Waterloo Building Department:.A. permanent electrical and lights. B. Permanent heat C.ADA compliance. D.required landing.E.required door width and hardware. F.flammable wall coverings.G. Proper zoning and parking with Planning Department. FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing ignition sources. devices and combustible materials,shall be maintained in an approved manner. Inspector:JEFF SIEBEL-Comments:portable electric heaters operating near combustibles.Remove heaters. FAIL 3107.13-LP-gas. The storage,handling and use of LP-gas and LP-gas equipment shall be in accordance with Sections 3107.13.1 through 3107.13.3. Inspector:JEFF SIEBEL-Comments: Remove L.P.gas cylinders from building.Must be stored outside chained in an upright position. FAIL 505.1 -Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:JEFF SIEBEL-Comments: Install permanent address on building in contrasting colors to the back ground. Printed on 02/09/2023 @ 10:35 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:Remove obstructions,Maintain a minimum of 36" clearance to electrical panel and disconnects. FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:remove all extension cords including to lights and electric heaters. Install permanent lighting and outlets with permits and inspections. FAIL 603.9.4-Prohibited areas. Portable,electric space heaters shall not be operated within 3 feet(914 mm)of any combustible materials. Portable,electric space heaters shall be operated only in locations for which they are listed. Inspector:JEFF SIEBEL-Comments:Remove portable electric heaters from store. Install permanent heat with permits and inspections. FAIL 803.1.2-Interior wall and Interior wall and ceiling finishes shall be classified in accordance with ASTM E84 or UL ceiling finish materials tested 723.Such interior finish materials shall be grouped in the following classes in in accordance with ASTM E84 accordance with their flame spread and smoke-developed indices:Class A:Flame or UL 723. spread index 0-25;smoke-developed index 0-450.Class B: Flame spread index 26-75; smoke-developed index 0-450.Class C: Flame spread index 76-200;smoke-developed index 0-450.Exception:Materials tested in accordance with Section 803.1.1 and as indicated in Sections 803.1.3 through 803.15. Inspector:JEFF SIEBEL-Comments: Install sheetrock over paper backed insulation on walls and ceiling. Paper insulation backed insulation listing requires applicable covering.Obtain permit and inspections. Printed on 02/09/2023 @ 10:35 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B,E,F,H, I,M,R-1,R-2,R-4 and S occupancies.Exceptions: 1.In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3.Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group I-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas,including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector:JEFF SIEBEL-Comments: Install a currently serviced 2A-10BC fire extinguisher 4"to 5 feet above the floor in an readily accessible location. GENERAL NOTES JEFF SIEBEL-02/09/2023 @ 09:13 annual inspection$50 JEFF SIEBEL-02/09/2023 @ 09:41 JEFF SIEBEL-02/09/2023 @ 09:42 JEFF SIEBEL-02/09/2023 @ 09:42 JEFF SIEBEL-02/09/2023 @ 09:42 JEFF SIEBEL-02/09/2023 @ 09:43 Printed on 02/09/2023 @ 10:35 Page 3 of 4 GENERAL NOTES JEFF SIEBEL-02/09/2023 @ 09:43 JEFF SIEBEL-02/09/2023 @ 09:43 JEFF SIEBEL-02/09/2023 @ 09:44 JEFF SIEBEL-02/09/2023 @ 10:13 REINSPECTION DATE 03/08/2023 CONTACT SIGNATURE Dave Minty Signed on:02/09/2023 @ 10:33 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/09/2023 @ 10:33 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/09/2023 @ 10:35 Page 4 of 4