City of Waterloo
tER
WATERLOO FIRE RESCUE �P `
INSPECTION REPORT " .
FAST AND FRESH,2221 LOGAN AVE,BLDG 2221 LOGAN AVE,WATERLOO IA 50703
6`
DETAILS
Inspection Date:11/22/2022 i Inspection Type:Annual Inspection(1Yr) I Inspection Number:7323 i Shift: N/A Station: N/A
Unit: N/A ! Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a
ignition listed disposal container.Contents of such containers shall be removed and
disposed of daily.
Inspector:JEFF SIEBEL-Comments: provide approved listed oily waste container with
self-closing lid for all grease laden rags etc.
FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:repair egress light in men's restroom.
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments: Remove exit/egress light above hall to restrooms
in store and properly cover with a listed blank cover. Non-required Exit was
eliminated for storage use
FAIL 609.3.3.3-Records Records for inspections shall state the individual and company performing the
inspection,a description of the inspection and when the inspection took place.
Records for cleanings shall state the individual and company performing the cleaning
and when the cleaning took place.Such records shall be completed after each
inspection or cleaning and maintained.
Inspector:JEFF SIEBEL-Comments: provide current semi-annual kitchen hood
cleaning inspection report with all discrepancies corrected.Contractor must upload
report online to The Compliance Engine.
Printed on 1 1/23/2022 @ 10:32
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device, provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments: Provide annual service for fire extinguishers.
GENERAL NOTES
JEFF SIEBEL-11/23/2022 @ 10:30 Annual inspection$80
REINSPECTION DATE
12/14/2022
CONTACT SIGNATURE
Michelle Wubbena-AST. Manager
Signed on: 11/23/2022 @ 10:28 d
[r,
i-L
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 11/23/2022 @ 10:28
Printed on 11/23/2022 @ 10:32