Loading...
HomeMy WebLinkAbout2221 LOGAN AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE sf■a iat 02/16/2023 03/20/2023 2023-00011167 $80.00 •°1erloo) Customer#: 24038 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable FAST AND FRESH 715 Mulberry St 2221 LOGAN AVE WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2221 LOGAN AVE- 11-22-22 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24038 02/16/2023 03/20/2023 2023-00011167 $80.00 Less Prepayment $0.00 Total Due -* $80.00 City of Waterloo tER WATERLOO FIRE RESCUE �P ` INSPECTION REPORT " . FAST AND FRESH,2221 LOGAN AVE,BLDG 2221 LOGAN AVE,WATERLOO IA 50703 6` DETAILS Inspection Date:11/22/2022 i Inspection Type:Annual Inspection(1Yr) I Inspection Number:7323 i Shift: N/A Station: N/A Unit: N/A ! Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a ignition listed disposal container.Contents of such containers shall be removed and disposed of daily. Inspector:JEFF SIEBEL-Comments: provide approved listed oily waste container with self-closing lid for all grease laden rags etc. FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light in men's restroom. FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments: Remove exit/egress light above hall to restrooms in store and properly cover with a listed blank cover. Non-required Exit was eliminated for storage use FAIL 609.3.3.3-Records Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments: provide current semi-annual kitchen hood cleaning inspection report with all discrepancies corrected.Contractor must upload report online to The Compliance Engine. Printed on 1 1/23/2022 @ 10:32 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: Provide annual service for fire extinguishers. GENERAL NOTES JEFF SIEBEL-11/23/2022 @ 10:30 Annual inspection$80 REINSPECTION DATE 12/14/2022 CONTACT SIGNATURE Michelle Wubbena-AST. Manager Signed on: 11/23/2022 @ 10:28 d [r, i-L INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11/23/2022 @ 10:28 Printed on 11/23/2022 @ 10:32 Page 2 of 3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 1 1/23/2022 @ 10:32 Page 3of3