Loading...
HomeMy WebLinkAbout1120 W 4TH ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE /04 rirp: 11/21/2022 12/26/2022 2023-00011063 $50.00 VNite Customer#: 23973 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WEST SPA SUITES 715 Mulberry St 1120 W 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1120 W 4TH ST- 10-6-22 FOR BILLING INQUIRY: (319)291-4323 LDescription ( Total Price INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23973 11/21/2022 12/26/2022 2023-00011063 $50.00 Less Prepayment $0.00 Total Due —* $50.00 City of Waterloo c0 WATERLOO FIRE RESCUE , �g R{�0 �, \\ c) INSPECTION REPORT ii WEST SPA SUITES, 1120 W 4TH ST,BLDG 1120 W 4TH ST,WATERLOO IA 50702 DETAILS Inspection Date:10/06/2022 i Inspection Type:Annual Inspection(1Yr) l Inspection Number: 1433 I Shift: N/A l Station: N/A Unit: N/A l Lead Inspector:JEFF SIEBEL Other Inspectors:JEREMIAH VANDYKE, BROCK WELIVER Fee:$50.00 STATUS CODE DESCRIPTION FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector:JEFF SIEBEL-Comments: Remove extension cords. Install permanent outlet or you may utilize power taps with a manual reset. Power tap may be used for computers,electronics etc,but not for items containing motors or produce heat or cooling. FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector:JEFF SIEBEL-Comments:provide documentation of dryer vent cleaning to the outside with signature and date. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B,E, F,H,I, M, R-1,R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:JEFF SIEBEL-Comments: Install currently serviced 2A-10BC fire extinguisher 4"to 5'above the floor in an accessible location.One upstairs and one downstairs. Printed on 10/10/2022 @ 11:03 Page 1 of 3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 10/10/2022 @ 11:03 Page 3 of 3