Loading...
HomeMy WebLinkAbout3251 GREYHOUND DR ~�. INVOICE DATE DUE DATE INVOICE# TOTAL DUE ��11�i�1'I ram: ���� 11/21/2022 12/26/2022 2023-00011070 $80.00 4terloo o Customer#: 23977 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable LOVES TIRE SHOP 715 Mulberry St 3251 GREYHOUND DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3251 GREYHOUND DR- 10-17-22 FOR BILLING INQUIRY: (319)291-4323 I LDescription i Total Price J INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER# I BILLING DATE I DUE DATE 23977INVOICE# CHARGES 11/21/2022 12/26/2022 I 2023-00011070 $80.00 _ Less Prepayment $0.00 Total Due $80.00 City of Waterloo 7 s �n WATERLOO FIRE RESCUE � i �p Roo CO,O, INSPECTION REPORT �, II: LOVE'S TIRE SHOP,3251 GREYHOUND DR,BLDG 3251 GREYHOUND DR., WATERLOO IA 50702 444011 DETAILS Inspection Date: 10/17/2022 ; Inspection Type:Annual Inspection(1Yr) Inspection Number:9002 Shift: N/A I Station: N/A Unit: N/A i Lead Inspector:JEFF SIEBEL ! Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall <— 6jy be used only with portable appliances. Inspector:JEFF SIEBEL-Comments:remove extension cord to tv monitor� ' by office door in shop. Install permanent outlet with permits and inspections. FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for ; F listing the opening protective. Fire doors and smoke barrier doors shall not be p g - . blocked or obstructed,or otherwise made inoperable.Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector:JEFF SIEBEL-Comments:remove hose from fire door drop area to allow proper�. ro er seal. Printed on 10/18/2022 @ 10:20 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: Provide annual service for all fire extinguishers. Extinguisher by drop door has been expelled. Provide maintenance. GENERAL NOTES JEFF SIEBEL-10/18/2022 @ 10:19 annual inspection$80 REINSPECTION DATE 11/07/2022 CONTACT SIGNATURE Jim Wellner LSigned on: 10/18/2022 @ 10:17 a , LI 7-C C__/i/L_1__r INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 10/18/2022 @ 10:17 Printed on loll 8/2022 @ 10:20 Page 2 of 3 QUESTIONS AMOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 10/18/2022 @ 10:20 Page 3 of 3