COMMERCIAL INSPECTION- 1930 HAWTHORNE AVE- 10-7-22
FOR BILLING INQUIRY: (319)291-4323
LDescription r rr
Total Price J
INSPECTION 1
OCCUPANCY FEE $40.00
$10.00
CUSTOMER# BILLING DATE DUE DATE
23978 I 11/21/2022 INVOICE# CHARGES
12/26/2022 2023-00011071 $50.00
Less Prepayment $0.00
Total Due—> $50.00
City of Waterloo
WATERLOO FIRE RESCUE u �pSERCpO
INSPECTION REPORT
ASIAN DAY SPA,1930 HAWTHO ii
RNEAVE,BLDG 1930 HAWTHORNEAVE,WATERLOO IA S0702 44400
DETAILS
Inspection Date:10/07/2022 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:1542 I Shift: N/A I Station: N/A
Unit: N/A 3 Lead Inspector:JEREMIAH VANDYKE I Other Inspectors:BROCK WELIVER I Fee:$50.00
STATUS CODE DESCRIPTION
FAIL 102.3-Change of use or Changes shall not be made in the use or occupancy of any structure that would place
occupancy the structure in a different division of the same group or occupancy or in a different
group of occupancies,unless such structure is made to comply with the
requirements of this code and the International Building Code. Subject to the
approval of the fire code official,the use or occupancy of an existing structure shall
be allowed to be changed and the structure is allowed to be occupied for purposes in
other groups without conforming to all of the requirements of this code and the
International Building Code for those groups,provided the new or proposed use is
less hazardous, based on life and fire risk,than the existing use.
Inspector:JEREMIAH VANDYKE-Comments: Building is not constructed to a
residential standard. No one is to be living in the Asian Spa Business The building
would require safety improvements to meet residential standards.Two complete
beds and bedding were located in the back of business other than massage tables.
There is a stock of food and cooking appliances,wardrobe of clothing,and beds. 1.
Beds X2 in back must be removed by Monday,October 17th.
FAIL 102.4-Application of building The design and construction of new structures shall comply with the International
code Building Code,and anyalterations,
additions,changes in use or changes in
structures required by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
Inspector:JEREMIAH VANDYKE-Comments:Obtain plumbing permit and inspection
for shower installed in backroom.If any electrical work is to be completed an
electrical permit must be obtained.
i
M*,ajWt- OaVita
a
Printed on 10/10/2022 @ 09:25
Page 1 of 9
STATUS CODE DESCRIPTION
IL 605.10.4-Prohibited areas Portable,electric space heaters shall not be operated within 3 feet(914 mm)of any
combustible materials. Portable,electric space heaters shall be operated only in
locations for which they are listed.
Inspector:JEREMIAH VANDYKE-Comments:Space heater located in back room
plugged into extension cord. Needs to be removed.
y
FAIL 605.4-Multiplug adapters Multiplug adapters,such as cube adapters, unfused plug strips or any other device
not complying with NFPA 70 shall be prohibited.
Inspector:JEREMIAH VANDYKE-Comments: Multiplug adapters located throughout
business that are not approved. Multiplug adapters are plugged into each other
(Daisy chained).
•
•
'
5 max.1
411
c �
Printed on 10/10/2022 @ 09'25
Page 3 of 9
STATUS CODE DESCRIPTION
Inspector:JEREMIAH VANDYKE-Comments:
FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings,nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
be used only with portable appliances.
Inspector:JEREMIAH VANDYKE-Comments:
Printed on 10/10/2022 @ 09:25
Page 5 of 9
STATUS CODE DESCRIPTION
FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged,altered, breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resistance-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector:JEREMIAH VANDYKE-Comments:Ceiling tiles in back room are missing or
damaged. Must be repaired or replaced.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A, B, E,F,H, I, M,R-1,R-2, R-4 and S occupancies. Exception:In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:JEREMIAH VANDYKE-Comments:No fire extinguishers located in building.
Must have receipt of purchase.
FAIL 906.5-Conspicuous location Portable fire extinguishers shall be located in conspicuous locations where they will
be readily accessible and immediately available for use.These locations shall be
along normal paths of travel,unless the fire code official determines that the hazard
posed indicates the need for placement away from normal paths of travel.
Inspector:JEREMIAH VANDYKE-Comments: No fire extinguishers located in building.
FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms
unobscured or areas in which visual obstruction cannot be completely avoided, means shall be
provided to indicate the locations of extinguishers.
Inspector:JEREMIAH VANDYKE-Comments:No fire extinguishers located in building.
Printed on 10/10/2022 @ 09:25
Page 7 of 9
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on: 10/10/2022 @ 09:14