Loading...
HomeMy WebLinkAbout845 W 4TH ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE i 41 W- 11/21/2022 12/26/2022 2023-00011081 $80.00 _siP c?ietJoo Ao Customer#: 23763 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HOUSE OF HOPE 715 Mulberry St 845 W 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 845 W 4TH ST- 11-21-22 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23763 11/21/2022 12/26/2022 2023-00011081 $80.00 Less Prepayment $0.00 Total Due —> $80.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT HOUSE OF HOPE-LEGACY LITTLES,845 W 4TH ST,BLD6 845 W 4TH ST,WATERLOO IA 50702 4 DETAILS Inspection Date: 11/21/2022 Inspection Type:Annual Inspection(1Yr) ! Inspection Number:7375 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION 403.10.2.1.1 -First emergency The first emergency evacuation drill of each school year shall be conducted within 10 evacuation drill days of the beginning of classes. Inspector:JEREMIAH VANDYKE-Comments: Please send me a recorded of date of fire drill last completed. FAI L 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments:Exit sign tested and failed. Located in basement hallway near middle steps near sprinkler riser room. FAIL, 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction, including, but not limited to,walls,firestops,shaft enclosures, partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEREMIAH VANDYKE-Comments:Wine/storage room in basement has propped open door to furnace room. Printed on 11/21/2022 @ 15:01 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 903.3.1 -Standards Sprinkler systems shall be designed and installed in accordance with Section 903.3.1.1,unless otherwise permitted by Sections 903.3.1.2 and 903.3.1.3 and other chapters of this code,as applicable. Inspector:JEREMIAH VANDYKE-Comments: Deficiency on Compliance Engine:Three year trip test will be due on dry sprinkler system in warmer weather.Please schedule with licensed sprinkler contractor for to have corrected in warmer weather. GENERAL NOTES JEREMIAH VANDYKE-11/21/2022 @ 14:41 Max#of Children Allowed=4.All children are 2.5 years old or younger. JEREMIAH VANDYKE-11/21/2022 @ 14:44 01/05/2022 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-11/21/2022 @ 14:44 01/05/2022 S-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Deficient JEREMIAH VANDYKE-11/21/2022 @ 14:46 Fire Extinguishers are compliant/serviced by Pro shield in December 2021. Due for service next month. JEREMIAH VANDYKE-11/21/2022 @ 14:46 Clothes dryer serviced by Harris Cleaning 7/5/2022. JEREMIAH VANDYKE-11/21/2022 @ 14:47 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-11/21/2022 @ 14:47 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-11/21/2022 @ 14:47 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-11/21/2022 @ 14:59 Inspection Fee=$80.00-will be scheduling next annual inspection in October/November 2023. Printed on 11/21/2022 @ 15:01 Page 2 of 3 GENERAL NOTES JEREMIAH VANDYKE-11/21/2022 @ 14:58 Please check apartment rooms for any heating devices(refrigerators,microwaves, coffee makers,and heaters plugged into power strips or extension cords.They must be plugged directly into wall outlets. REINSPECTION DATE 12/21/2022 CONTACT SIGNATURE Chassidi Martin-Royal Legacy Christian Contact Refused Academy Refusal Reason: N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 11/21/2022 @ 15:00 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 11/21/2022 @ 15:01 Page 3of3