Loading...
HomeMy WebLinkAbout3280 UNIVERSITY AVE (2) r_y\ a;WATERLOO FIRE RESCUE t►� o INSPECTION REPORT �1tit TR/-COUNTY HEADSTART,3280 UNIVERSITY AYE,BLDG 3280 UNIVERSITY AVE,WATERLOO IA 50701 4410 DETAILS Inspection Date: 11/21/2022 Inspection Type:Annual Inspection(1Yr) E Inspection Number: 1113 Shift: N/A Station: N/A Unit: N/A = Lead Inspector:JEFF SIEBEL Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening force The force for pushing or pulling open interior swinging egress doors,other than fire doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments: repair exit door from kitchen. Must unlatch and swing to full open with less than 15#force FAIL 506.2-Key box maintenance The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEFF SIEBEL-Comments: Provide current key for Knox Box(fire fighter access).Call Inspector Van Dyke 319-883-1615 to lock in correct key. FAIL 609.3.3.3-Records Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments: Provide documentation of kitchen hood fire suppression inspections report with all discrepancies corrected.Contractor must upload online to the compliance engine. Printed on 1 1/22/2022 @ 09:24 Page 1 of 3 STATUS CODE DESCRIPTION FAI L 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction, including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered,breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEFF SIEBEL-Comments: Replace missing ceiling tile in old water heater room. 903.3.1 -Standards Sprinkler systems shall be designed and installed in accordance with Section 903.3.1.1,unless otherwise permitted by Sections 903.3.1.2 and 903.3.1.3 and other chapters of this code,as applicable. Inspector:JEFF SIEBEL-Comments: Provide access for fire inspector to fire sprinkler room. GENERAL NOTES JEFF SIEBEL-11/22/2022 @ 08:58 annual inspection$80 JEFF SIEBEL-11/22/2022 @ 09:12 Occupant states that large stove is disconnected and just stored in kitchen,and only rewarming and water boiling is all that is done in kitchen. JEFF SIEBEL-11/22/2022 @ 09:12 hours are 6A to 230P with lunch 11-12 REINSPECTION DATE 12/13/2022 Printed on 11/22/2022 @ 09:24 Page 2 of 3 CONTACT SIGNATURE Lyz Schmitz &, 8 / 6 Signed on: 11/22/2022 @ 09:09 yy INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11/22/2022 @ 09:09 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11/22/2022 @ 09:24 Page 3 of 3