Loading...
HomeMy WebLinkAbout1215 ANSBOROUGH AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE fb4 �1'4 11/17/2022 12/20/2022 2023-00010988 $80.00 ferloo �o Customer#: 6293 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BURGER KING 715 Mulberry St 1215 ANSBOROUGH AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1215 ANSBOROUGH AVE- 9-20-22 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 6293 11/17/2022 12/20/2022 2023-00010988 $80.00 Less Prepayment $0.00 Total Due --> $80.00 City of Waterloo '...41;\'3 WATERLOO FIRE RESCUE �P�EA�oo 4440 INSPECTION REPORT t 4i BURGER KING,1215 ANSBOROUGH AVE,BLDG 1215 ANBOROUGH AVE, WATERLOO/A 50701 DETAILS Inspection Date:09/20/2022 I Inspection Type:Annual Inspection(1Yr) Inspection Number:622 I Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments: Egress light tested and failed. 1.Located _=- in mens restroom.2.Located in- kitchen area above warming trey. W 0 * 4 may = FAIL 604.2.5-Exit signs Emg pwe fgne3 systemer shall ency beo er capableshall be of provid powerindg theorexit required si s as load required for a duration inS ction of not101 less.6.3.thanThe 90 minutes. IInspector:JEREMIAH VANDYKE-Comments: Exit light tested and failed. Located near main entrance. 1 ,, ■ i kaa f - d f�- FAIL 605.4.2-Power supply Relocatable power taps shall be directly connected to a permanently installed receptacle. Printed on 09/20/2022 @ 15:33 Page 1 of 3 STATUS CODE DESCRIPTION Inspector:JEREMIAH VANDYKE-Comments: Power tap hanging needs to be secured ` as described above. Located at pickup window area. • FA I L 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such y' elements shall be visually inspected by the owner annually and properly repaired, 6 restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall tom, p p not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke - and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEREMIAH VANDYKE-Comments: Missing ceiling tile above pickup/order booth area. FAI 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met:2.1. Electronic Novo X.fe.e 'f,-od , monitoring shall confirm that extinguishers are properly positioned, properly 441� charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic g supervisoryevery years monitorin devices and su ervisor circuits shall be tested 3 when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments: Fire extinguishers due for service. GENERAL NOTES Printed on 09/20/2022 @ 15:33 Page 2 of 3 JEREMIAH VANDYKE-09/20/2022 @ 15:32 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-09/20/2022 @ 15:33 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-09/20/2022 @ 15:33 Inspection Fee=$80.00 JEREMIAH VANDYKE-09/20/2022 @ 15:33 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. REINSPECTION DATE 10/20/2022 CONTACT SIGNATURE Andrea Navenma Signed on:09/20/2022 @ 10:22 \t INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:09/20/2022 @ 10:22 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 09/20/2022 @ 15:33 Page 3 of 3