COMMERCIAL INSPECTION-200 E ARLINGTON ST- 10-10-22 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price J
REINSPECTION 3 $200.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
22864 11/17/2022 12/20/2022 2023-00010990 $200.00
Less Prepayment $0.00
Total Due $200.00
City of Waterloo
WATERLOO FIRE RESCUE INSPECTION REPORT
ROOSEVELT SENIOR HOUSING 200 EARL►NGTON T S ,BLD6 200 EARL/N6TON ST, WATERLOO
IA 50703 440
DETAILS
Inspection Date: 10/10/2022 I Inspection Type: Residential Common Areas Inspection j Inspection Number:8692 I Shift: N/A
Station: N/A I Unit: N/A ! Lead Inspector:JEREMIAH VANDYKE ; Other Inspectors: N/A Fee:$200.00
C.
STATUS CODE DESCRIPTION P—Q— jK.Q10
FAIL 1104.16.5.1 -Examination Fire escape stairways and balconies shall be examined for structural adequacy and
safety in accordance with Section 1104.16.5 by a registered design professional or
others acceptable to the fire code official every 5 years,or as required by the fire
code official.An inspection report shall be submitted to the fire code official after
such examination.
Inspector:JEREMIAH VANDYKE-Comments: Report needed for fire escape stairs as
described above by registered design engineer professional.
FAIL 404.2.1 -Fire evacuation plans Fire evacuation plans shall include the following: 1. Emergency egress or escape
routes and whether evacuation of the building is to be complete by selected floors or
areas only or with a defend-in-place response.2. Procedures for employees who
must remain to operate critical equipment before evacuating.3. Procedures for the
use of elevators to evacuate the building where occupant evacuation elevators
complying with Section 3008 of the International Building Code are provided.4.
Procedures for assisted rescue for persons unable to use the general means of
egress unassisted.5. Procedures for accounting for employees and occupants after
evacuation has been completed.6. Identification and assignment of personnel
responsible for rescue or emergency medical aid.7.The preferred and any
alternative means of notifying occupants of a fire or emergency.8.The preferred and
any alternative means of reporting fires and other emergencies to the fire
department or designated emergency response organization.9. Identification and
assignment of personnel who can be contacted for further information or
explanation of duties under the plan. 10.A description of the emergency voice/alarm
communication system alert tone and preprogrammed voice messages,where
provided.
Inspector:JEREMIAH VANDYKE-Comments:Copy of fire evacuation plans that
tenants should follow in case of a fire.
Printed on 10/10/2022 @ 15:16
Page 1 of 4
STATUS CODE DESCRIPTION
d electrical
FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of
inspecte equipment by an approved agency and installed and maintained
in accordance with all instructions included as part of such listing.
Inspector:JEREMIAH VANDYKE-Comments:Exhaust Duct system must be cleaned
from the dryer to the outside documented by who and when serviced. -2021 Code
610.1.2 Maintenance.The lint trap,mechanical and heating components,and the
f4:9, exhaust duct system of a clothes dryer shall be maintained in accordance with the
%� manufacturer's operating instructions to prevent the accumulation of lint or debris
that pow
revents the exhaust of air and products of combustion. Pictures from laundry
� a room on all 3 floors behind dryers.
tom ,.
iT !iiIJi
S ?-2-,,
I i tt %�/
s
I 13.171 iiiL. s -w v:',
it ",..
y9
j
FAIL 99999-Inspection Outcome Did the inspection pass or fail?
Inspector:JEREMIAH VANDYKE-Comments:Secured front entrance door is broke and
I was able to enter the building to complete re inspection.
GENERAL NOTES
Printed on 10/10/2022 @ 15:16