Loading...
HomeMy WebLinkAbout244 ASH ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE i/kr1aF■rn ter„; 11/17/2022 12/20/2022 2023-00010991 $80.00 taeterloo \o Customer#: 11613 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable KNIGHTS OF PYTHIAS 715 Mulberry St 244 ASH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-244 ASH ST-9-28-22 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 11613 11/17/2022 12/20/2022 2023-00010991 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo WATERLOO FIRE RESCUE 4p�ERL.00 INSPECTION REPORT KNIGHTS OF PYTHIAS-FURGERSON LODGE#5,244 ASH ST,BLDG 244 ASH ST,WATERLOO IA 50703 440 DETAILS Inspection Date:09/28/2022 Inspection Type:Annual Inspection(1Yr) Inspection Number:6409 { Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A ; Fee:$80.00 STATUS CODE DESCRIPTION FAI 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments: Repair exit lights:A.above main door. B.Bar Side. FAI 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:JEFF SIEBEL-Comments: Properly restrain electrical wire going to yard light.Secure above egress path. FAI L 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:Provide annual service for fire extinguishers or attach receipt with date of purchase on bottom of fire extinguishers. GENERAL NOTES JEFF SIEBEL-09/28/2022 @ 15:21 annual inspection$80 Printed on 09/28/2022 @ 15:26 Page 1 of 2 GENERAL NOTES JEFF SIEBEL-09/28/2022 @ 15:24 new hood requires hvac permit for completion. REINSPECTION DATE 10/18/2022 CONTACT SIGNATURE Robert Mosley Signed on:09/28/2022 @ 15:25 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:09/28/2022 @ 15:25 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 09/28/2022 @ 15:26 Page 2of2