COMMERCIAL INSPECTION - 3301 GREYHOUND DR- 10-17-22 FOR BILLING INQUIRY: (319)291-4323
LDescription I Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23121 11/17/2022 12/20/2022 2023-00011003 $80.00
Less Prepayment $0.00
Total Due —> $80.00
City of Waterloo
.\
WATERLOO FIRE RESCUE :- � oo
INSPECTION REPORT " '`
LOVES COUNTRY STORE,3301 GREYHOUND DR,BLDG 3301 GREYHOUND DR, WATERLOO IA
50701 440)
DETAILS
Inspection Date: 10/17/2022 I Inspection Type:Annual Inspection(1Yr) Inspection Number:7159 Shift: N/A ; Station: N/A
Unit: N/A I Lead Inspector:JEFF SIEBEL Other Inspectors: N/A
1().
STATUS CODE DESCRIPTION
FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in
clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical
service equipment.Where the electrical service equipment is wider than 30 inches
(762 mm),the working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access
openings into attics or under-floor areas which provide a minimum clear opening of
22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments:remove obstructions to disconnects in storage
room behind truck fuel counter. Maintain 36"clearance as signed.
FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings,nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
be used only with portable appliances.
Inspector:JEFF SIEBEL-Comments: Remove extension cord from pump in water
softener room. Install permanent outlet for pump.
FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of
inspected electrical equipment by an approved agency and installed and maintained
in accordance with all instructions included as part of such listing.
Inspector:JEFF SIEBEL-Comments: Provide documentation of dryer vent pipe
cleaning to the outside of the building.
Printed on 10/18/2022 @ 08:53
Page 1 of 3
STATUS CODE DESCRIPTION
FAI 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction, including,
but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged,altered, breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resistance-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile by shower.
FAI L 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions:1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device, provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments: provide annual service for fire extinguishers.
GENERAL NOTES
JEFF SIEBEL-10/18/2022 @ 08:52 Fire Sprinkler and Fire Alarm current through Dec and Jan.
JEFF SIEBEL-10/18/2022 @ 08:40 Annual Inspection$80.
JEFF SIEBEL-10/18/2022 @ 08:44 Fire door drop test 9/17/22
Printed on 10/18/2022 @ 08:53
Page 2 of 3
REINSPECTION DATE
11/07/2022
CONTACT SIGNATURE
Jim Weliner
Signed on: 10/18/2022 @ 08:33
vv-\
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 10/18/2022 @ 08:33