Loading...
HomeMy WebLinkAbout2011-LA PORTE RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE /4.raprit .i 11/17/2022 12/20/2022 2023-00011015 $100.00 iPVi°Iterloo �o Customer#: 5002 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable COMFORT INN -WATERLOO 715 Mulberry St 2011 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -2011 LA PORTE RD- 10-19-22 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5002 11/17/2022 12/20/2022 2023-00011015 $100.00 Less Prepayment $0.00 Total Due— $100.00 City of Waterloo t V k Op WATERLOO FIRE RESCUE 4�T ER`°° INSPECTION REPORT COUNTRY INN&SUITES,4025 HAMMOND AVE BLDG 4025 HAMMOND AVE,WATERLOO/A424050702 DETAILS Inspection Date:10/19/2022 Inspection Type:Annual Inspection(1Yr) Inspection Number:7122 Shift: N/A ; Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE ; Other Inspectors: N/A ; Fee:$100.00 STATUS CODE DESCRIPTION 1103.8 Single-and multiple Single-and multiple station smoke alarms shall installed in 10existing. .3. Group I-1 and statio ben smoke alarms R occupancies in accordance with Sections 1103.8.1 through 138 Inspector:JEREMIAH VANDYKE Comments:Smoke alarms tested and failed in rooms: #129,#215 living room area,#219,#229 very quiet alarm,#310,#315 living room area,#320,#327. 509.1 -Identification Fire protection equipment shall be identified in an approved manner.Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements shall be identified for the use of the fire department.Approved signs required to identify fire protection equipment and equipment location shall be constructed of durable materials, permanently installed ,;z,:.,,:,..„4,?;,,,,:„,*.,0=--*,I, - i ' and readily visible. "� ��"` Inspector:JEREMIAH VANDYKE-Comments: Fire sprinkler riser room must be replaced back on door. !$ y .� ' :7:::.-7::::71, :,79:7:1„-:70-';', t-,e_,,____,'Nk'---- a 71_:".7'-om �� ii- Printed on 10/19/2022 @ 10:10 Page 1 of 6 STATUS CODE DESCRIPTION FAIL 509.2-Equipment access Approved access shall be provided and maintained for all fire protection equipment to permit immediate safe operation and maintenance of such equipment.Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. 1111 Inspector:JEREMIAH VANDYKE-Comments:Storage must be clear on 2nd and 3rd floor house keeping rooms from Sprinkler riser components. FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments: Egress light tested and failed located in Pool area near hot tub. 4111"— hr FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. y Inspector:JEREMIAH VANDYKE-Comments: Exit light tested and failed located on 2nd floor in hallway near room#209. F " T.T. Printed on 10/19/2022 @ 10:10 Page 2of6 STATUSDESCRIPTION CODE 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. kt Inspector:JEREMIAH VANDYKE-Comments:Open fuse box that is corroded located %, on ceiling in chemical/mechanical room that is hazard and must be abated. j 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches (762 mm),the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. %�o Exceptions: 1.Where other dimensions are required or allowed byNFPA 70.2.Access i p q %j '- _ � openings into attics or under-floor areas which provide a minimum clear opening of � 22 inches(559 mm)by 30 inches(762 mm). s Inspector:JEREMIAH VANDYKE-Comments:Storage must be cleared as described ue above on 2nd and 3rd floor housekeeping rooms. y italF-a -- . ----- -, r 4 , -- Printed on 10/19/2022 @ 10:10 Page 3 of 6 STATUS CODE DESCRIPTION FAIL 605.6-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditions shall be provided for all switch and electrical outlet boxes. Inspector:JEREMIAH VANDYKE-Comments:Open junction box located on pool chemical/mechanical room. sow .mar FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector:JEREMIAH VANDYKE-Comments:ALL GUEST AND HOTEL's DRYER Exhaust Duct system must be cleaned from the dryer to the outside documented by who and when serviced.----2021 Code-610.1.2 Maintenance.The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures, partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is woeaccessible by the removal or movement of a panel,access door,ceiling tile or similar .; movable entry to the space.Openings made therein for the passage of pipes, • electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEREMIAH VANDYKE-Comments:Hole in ceiling must be repaired, located on chemical/mechanical pool room. Printed on 10/19/2022 @ 10:10 Page 4of6 STATUS CODE DESCRIPTION FAIL 703.2.3-Door operation Swinging fire doors shall close from the full-open position and latch automatically. The door closer shall exert enough force to close and latch the door from any partially open position. Inspector:JEREMIAH VANDYKE-Comments: 1.Double swinging fire rated doors on ram , 3rd floor elevator area not shutting and LATCHING correctly.2.Room#329 door does not close and latch properly. - is-uo 1,1 totoil t g t GENERAL NOTES JEREMIAH VANDYKE-10/19/2022 @ 10:00 Fire extinguishers compliant/serviced. JEREMIAH VANDYKE-10/19/2022 @ 10:04 08/31/2022 5-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Compliant JEREMIAH VANDYKE-10/19/2022 @ 10:04 11/05/2021 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-10/19/2022 @ 10:09 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-10/19/2022 @ 10:09 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-10/19/2022 @ 10:09 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-10/19/2022 @ 10:10 Inspection Fee=$100.00 REINSPECTION DATE 11/18/2022 Printed on 10/19/2022 @ 10:10 Page 5of6 CONTACT SIGNATURE Shannon Cannon Contact Refused Refusal Reason: N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE j� tiL Signed on:10/19/2022 @ 10:00 U� _) QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 10/19/2022 @ 10:10 Page 6 of 6