Loading...
HomeMy WebLinkAbout1925 LA PORTE RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE it"1 ipo ,r"; 11/17/2022 12/20/2022 2023-00011013 $80.00 _miP Customer#: 5403 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BURGER KING 715 Mulberry St 1925 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1925 LA PORTE RD - 9-20-22 FOR BILLING INQUIRY: (319)291-4323 Description J Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5403 11/17/2022 12/20/2022 2023-00011013 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo WATERLOO FIRE RESCUE �PT�RLOQ INSPECTION REPORT BURGER KING,109 JEFFERSON ST,BLDG 109 JEFFERSON ST,WATERLOO IA 50702 4410 DETAILS Inspection Date:09/20/2022 Inspection Type:Annual Inspection(1Yr) I Inspection Number:8774 I Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector:JEREMIAH VANDYKE-Comments:Fire alarm in trouble mode. Needs to be addressed by licensed fire alarm contractor. FAIL 315.3.3-Equipment rooms Combustible material shall not be stored in boiler rooms, mechanical rooms, electrical equipment rooms or in fire command centers as specified in Section 508.1.5. Inspector:JEREMIAH VANDYKE-Comments: Main electrical room&Fire alarm control panel room needs to be clear of all storage. FAIL 509.1 -Identification Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements shall be identified for the use of the fire department.Approved signs required to identify fire protection equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEREMIAH VANDYKE-Comments: Door needs to be label with"Fire Alarm Control Panel&Main Electrical Panel". Printed on 09/20/2022 @ 15:48 Page 1 of 4 STATUSDESCRIPTION CODE FAIL 509.2-Equipment access Approved access shall be provided and maintained for all fire protection equipment to permit immediate safe operation and maintenance of such equipment.Storage, trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. y� Inspector:JEREMIAH VANDYKE-Comments: Room containing main electrical panel and fire alarm control panel needs to be clear of all storage. i - _itifi . ,_,,,,,,- . ,,,- - ' om, `- ice-� '� yr. / i FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments: Egress light tested and failed. Located in  kitchen. J �fil Printed on 09/20/2022 @ 15:48 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:JEREMIAH VANDYKE-Comments:1.Hanging light located in freezer.2. Open junction box in ordering booth. i y FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device, provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic ,may. monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic �y t monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments: Extinguishers due for service. FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments: Fire alarm inspection past due. Needs to be inspected by licensed fire alarm contractor and inspection report uploaded to Compliance engine by servicing contractor. GENERAL NOTES Printed on 09/20/2022 @ 15:48 Page 3 of 4 JEREMIAH VANDYKE-09/20/2022 @ 10:36 Fire extinguishers serviced/compliant by Synergy Fire on March 2022. JEREMIAH VANDYKE-09/20/2022 @ 15:47 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-09/20/2022 @ 15:47 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-09/20/2022 @ 15:47 Inspection Fee=$80.00 JEREMIAH VANDYKE-09/20/2022 @ 15:47 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. REINSPECTION DATE 10/20/2022 CONTACT SIGNATURE Rory Cagley-District Manager Signed on:09/20/2022 @ 10:44 INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:09/20/2022 @ 15:46 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 09/20/2022 @ 15:48 Page 4 of 4