Loading...
HomeMy WebLinkAbout127 JEFFERSON ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE Air1:1\lrrir. 11/17/2022 12/20/2022 2023-00011007 $200.00 kaifflite '14e/7oo o Customer#: 23091 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HAB PETROLEUM 715 Mulberry St 127 JEFFERSON WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 127 JEFFERSON ST- 8-17-22 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price J REINSPECTION 3 $200.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23091 11/17/2022 12/20/2022 2023-00011007 $200.00 Less Prepayment $0.00 Total Due—* $200.00 City of Waterloo ("):30 cA\ WATERLOO FIRE RESCUE .0TERLoo s INSPECTION REPORT HAB PETROLEUM, 127JEFFERSON ST,BLDG 127JEFFERSON ST,WATERLOO IA 50702 4401 DETAILS Inspection Date:08/17/2022 Inspection Type:Annual Inspection(1Yr) Inspection Number:8442 I Shift: N/A I Station: N/A Unit: N/A : Lead Inspector:JEFF SIEBEL Other Inspectors: N/A u),,z210 STATUS CODE DESCRIPTION FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:remove obstruction(old cooler)from exit path to back exit. FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit/egress sign above main door. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:JEFF SIEBEL-Comments:A.obtain permit and inspection and properly install light fixture in walk in cooler, hanging by wires without permit. Replace missing moisture proof light cover. B. properly mount electrical box by new cooler by rear exit. FAIL 605.4.2-Power supply Relocatable power taps shall be directly connected to a permanently installed receptacle. Inspector:JEFF SIEBEL-Comments:power strips are daisy chained by lottery machine. Each power strip must plug directly into wall outlet. FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector:JEFF SIEBEL-Comments:appliances with motors, produce heat or cooling must plug directly into power outlet. Relocated power cords:A. live bait cooler. Printed on 08/18/2022 @ 15:26 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile by Bank Shot Game. FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed. 2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: provide annual service for fire extinguishers. GENERAL NOTES JEFF SIEBEL-08/18/2022 @ 15:24 re-inspection fee$200 REINSPECTION DATE 09/09/2022 Printed on 08/18/2022 @ 15:26 Page 2of3 CONTACT SIGNATURE Mohammad Bhatti Signed on:08/18/2022 @ 15:24 '� c C! � ) t►- 1 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:08/18/2022 @ 15:24 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 08/18/2022 @ 15:26 Page 3 of 3