Loading...
HomeMy WebLinkAbout1945 LA PORTE RD -�►'���'� INVOICE DATE DUE DATE INVOICE# TOTAL DUE !k"g��\(•IrV:- 11/17/2022 12/20/2022 2023-00011014 $100.00 iNage �T4 Customer#: 13437 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BAYMONT INN 715 Mulberry St 1945 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1945 LA PORTE RD 10-11-22 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13437 11/17/2022 12/20/2022 2023-00011014 $100.00 Less Prepayment $0.00 Total Due —> $100.00 City of Waterloo n WATERLOO FIRE RESCUE - �,PZERtoo CV/NSPECT/ON REPORT BAYMONT INN&SUITES,1945 LA PORTE RD,BLDG 1945 LA PORTE RD,WATERLOO IA 50702 DETAILS Inspection Date: 10/11/2022 Inspection Type:Annual Inspection(1Yr) j Inspection Number:6833 Shift: N/A ! Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE 1 Other Inspectors: N/A Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1103.8-Single-and multiple- Single-and multiple-station smoke alarms shall be installed in existing Group I-1 and station smoke alarms R occupancies in accordance with Sections 1103.8.1 through 1103.8.3. Inspector:JEREMIAH VANDYKE-Comments:Smoke alarms tested and failed located in:#103,#114,#207,#222,and smoke alarm located above guest washer/dryer area on 1st floor. FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments: Egress light tested and failed located in hallway near room 204. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:JEREMIAH VANDYKE-Comments:Open wiring needs to be addressed located in pool chemical room for light fixture. Printed on 10/11/2022 @ 14:30 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector:JEREMIAH VANDYKE-Comments:All clothes dryers both guest and hotel's personal dryers must have exhaust Duct system must be cleaned from the dryer to the outside DOCUMENTED by who and when serviced.----2021 Code-610.1.2 Maintenance.The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector:JEREMIAH VANDYKE-Comments: 1.Missing fire door going into Electrical panel room, must be replaced with UL listed certified fire door.2. Door stops must be removed located on water heater door. Marked fire doors must not be blocked open. • sy_ 4 v Printed on 10/11/2022 @ 14:30 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 703.2.3-Door operation Swinging fire doors shall close from the full-open position and latch automatically. The door closer shall exert enough force to close and latch the door from any partially open position. Inspector:JEREMIAH VANDYKE-Comments:Doors did not fully latched located at rooms:#229 and#210.Explanation above. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E,F, H, I,M, R-1, R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible �-sj liquids are stored, used or dispensed.4.On each floor of structures under y yr construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. KSitragfi � Where required by the sections indicated in Table 906.1.6.Special-hazard areas, i ar including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:JEREMIAH VANDYKE-Comments: Missing fire extinguisher located on 2nd floor near room#216. GENERAL NOTES JEREMIAH VANDYKE-10/11/2022 @ 14:13 Fire extinguisher serviced/compliant by Hawkeye Fire on March 2022. JEREMIAH VANDYKE-10/11/2022 @ 14:27 04/22/2022 S-(Annual)Fire Alarm HAWKEYE COMMUNICATION Reviewed Compliant JEREMIAH VANDYKE-10/11/2022 @ 14:29 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-10/11/2022 @ 14:29 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-10/11/2022 @ 14:29 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-10/11/2022 @ 14:29 Inspection Fee=$100.00 Printed on 10/1 1/2022 @ 14:30 Page 3 of 4 REINSPECTION DATE 11/10/2022 CONTACT SIGNATURE Chirag Chaudhari Contact Refused Refusal Reason: N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 10/11/2022 @ 14:27 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 10/11/2022 @ 14:30 Page 4 of 4