Loading...
HomeMy WebLinkAbout2034 LA PORTE RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE / 4 la_ 11/17/2022 12/20/2022 2023-00011016 $100.00 °r°rl oo •o Customer#: 12855 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HAMPTON INN 715 Mulberry St 2034 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -2034 LA PORTE RD- 10-19-22 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12855 11/17/2022 12/20/2022 2023-00011016 $100.00 Less Prepayment $0.00 Total Due--> $100.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT . HAMPTON INN&SUITES,2034 LA PORTE RD,BLDG 2034 LA PORTE RD,WATERLOO IA 50702 DETAILS Inspection Date: 10/19/2022 I Inspection Type:Annual Inspection(1Yr) 1 Inspection Number:7452 Shift: N/A Station: N/A I Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A ; Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1103.8-Single-and multiple- Single-and multiple-station smoke alarms shall be installed in existing Group I-1 and station smoke alarms R occupancies in accordance with Sections 1103.8.1 through 1103.8.3. Inspector:JEREMIAH VANDYKE-Comments:Smoke alarms tested and failed in rooms: #128 and#220. s FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no and maintenance troubles,supervisory,or alarms)? Inspector:JEREMIAH VANDYKE-Comments:According to compliance engine website a deficiency was found by servicing fire alarm contractor:Answer: Horn Strobe Lobby East pillar 1st floor did not activate.After corrected by servicing fire alarm contractor change on compliance engine website by servicing contractor. Printed on 10/19/2022 @ 11:32 Page 1 of 4 STATUS CODE DESCRIPTION FAI L 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction, including, but not limited to,walls,firestops,shaft enclosures, partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space ace is accessible by the removal or movement of a panel,access door,ceiling tile or movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEREMIAH VANDYKE-Comments: Broken laundry chute door must self close and latch. Located on 4th floor. FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be / blocked or obstructed,or otherwise made inoperable.Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector:JEREMIAH VANDYKE-Comments: Marked fire doors can not be blocked , gym open. Located in guest laundry room. FAIL 703.2.3-Door operation Swinging fire doors shall close from the full-open position and latch automatically. The door closer shall exert enough force to close and latch the door from any partially open position. Inspector:JEREMIAH VANDYKE-Comments: Door did not close and latch properly room#328. GENERAL NOTES JEREMIAH VANDYKE-10/19/2022 @ 11:29 08/15/2022 S-(Semi-Annual)Fire Alarm MIDWEST ALARM SERVICES Reviewed Deficient JEREMIAH VANDYKE-10/19/2022 @ 11:30 06/17/2022 S-(Annual)Fire Sprinkler TRI-STATE AUTOMATIC SPRINKLER,INC. Reviewed Compliant Printed on 10/19/2022 @ 11:32 Page 2 of 4 GENERAL NOTES JEREMIAH VANDYKE-10/19/2022 @ 11:30 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-10/19/2022 @ 11:30 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-10/19/2022 @ 11:30 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-10/19/2022 @ 11:31 Inspection Fee=$100.00 JEREMIAH VANDYKE-10/19/2022 @ 11:11 Fire extinguisher's compliant. JEREMIAH VANDYKE-10/19/2022 @ 11:19 Dryers serviced by Harris on 3/1/2022. JEREMIAH VANDYKE-10/19/2022 @ 11:20 Fire drop door laundry chute located in Hotels'Washer and dryer area was serviced by Christie Door Company 2/27/2022. REINSPECTION DATE 11/18/2022 CONTACT SIGNATURE Cayenne Adams-Manager Contact Refused Refusal Reason:N/A emailed. INSPECTOR SIGNATURE JEREMIAH VANDYKE f Signed on: 10/19/2022 @ 11:32 'J�_/ Printed on 10/19/2022 @ 11:32 Page 3 of 4 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 10/19/2022 @ 11:32 Page 4 of 4