RENTAL INSPECTION - 1133 DIXON DR- 9-21-23 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24076 11/01/2023 12/10/2023 2024-00000072 $250.00
Less Prepayment $0.00
Total Due-* $250.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
.e.r
\�' �� (�v�
� `~'`
WATERLOO &��@��� �����
����� �J��m�n� �-�J�� RESCUE
INSPECTION REPORT
112S-1133 DIXON DRIVE CONDOMINIUMS BLDG, 1133 DIXON DR, WATERLOO 1A S0701
DcrxuS _
Inspection Date:00/21/2023 | Inspection Type: Rental Inspection | Inspection Number: 10912 Sh'fc N/A i Station: N/A �
Unit: N/A | Lead Inspector:BARRYSTRATT0N Other|nspectors' .N/A | Fee $350�0 �
.
STATUS CODE DESCRIPTION
FAIL 1008.1 Means ofegress Illumination shall be provided in the means of egress in accordance with Section
illumination. 1008.2. Under emergency power, means of egress illumination shall comply with
Secc\on1O08.l
Inspector: BARRYSTRATTOm Comments:Egress lighting does not work.Today's
inspections lights still do not work.
Location: Not Provided
FAIL 1032.2 ReUabi|iry. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions nr impediments tofull instant use in the case nffire or other
emergency where the building area served by the means of egress is Occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:BARRYSTRugTON Comments:Front door threshold is obstructing door
from closing.Threshold is still not repaired. Rear door is missing door hardware.
Location: Not Provided
FAIL 603.2 Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other eqUipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not beused.
Inspector:BARRYSTRAlTON Comments:AC disconnect box on East side ofbuilding
is hanging by wires. Box needs secured to building.AC disconnect box still hanging
from building. Box still hanging not secured to building
Location: Not Provided
'^""u on,
op'z �:��
Page 1or4
STATUS CODE DESCRIPTION
FAA 704.3-Opening protectives. Where openings are required to be protected, opening protectives shall be
maintained self-closing or automatic-closing by smoke detection. Existing fusible-link-
type automatic door-closing devices are permitted if the fusible link rating does not
exceed 135°F(57°C).
Inspector: BARRY STRATTON-Comments:Fire doors in open position. Fire doors still
left in the open position on todays inspection,may require door closures installed on
doors.
Location: Not Provided
FAIL 901.6-Inspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems,
maintenance. fire-extinguishing systems, mechanical smoke exhaust systems and smoke and heat
vents protection and life safety systems shall be maintained in an operative condition
at all times,and shall be replaced or repaired where defective. Nonrequired fire
protection and life safety systems and equipment shall be inspected,tested and
maintained or removed in accordance with Section 901.8 .
Inspector:BARRY STRATTON-Comments:Alarm need maintenance and testing.
Alarm testing still requires tested.Still not done.
Location: Not Provided
Printed on 09/21/2023 of.10:40
Page 2 of 4
`
S7mrmS CODE oeScnxmr/om
FAIL 906.1 Vvhererequired. Pot-table fire extinguishers shall be installed in all of the following locations: 1.111 new
and existing Group A` D' E' F, H' |./N' R,1' R-2' R~4 and S Occupancies. Exceptions: 1.1n
Group R-2 Occupancies, pot-table fire extinguishers shall be required only in locations
specified in Iterns 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having aminimum rating of1+\:1O'BI.2.|n Group EOccupancies,
pot-table fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a pot-table fire extinguisher having
a minimum rating ofZ-A:2U'B:C.3. In storage areas of Group 5 occupancies where
forklift,powered industrial truck or powered can operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use ofvehide'mounred extinguishers shall
be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10,
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on'sitetn replace adischarged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.3.5. Inspections o[vehicle-
mounted extinguishersshaUbeperformeddai|y.2.VVichin38feex(0144mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.1n areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
scruccuresunderconscrucrion. exceptGroupR'3occupancies' inaccordancewith
Section3316.1. 5.VVhere required by the sections indicated in Table 0D6.1.6.Specia|'
hazard areas, induding but not limited to laboratories, computer rooms and
generator rooms,where required by the fire code official. Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector: BARRv6TRATTON Comments:Fire Extinguishers need updated.(Z021).
Fire extinguishers still out of date(2021).
Location: Not Provided
FAfL R4 Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(|Px4[382)
Inspector: BAKRYSTR/QTON Comments:Front concrete slab atdnor. Busted
concrete missing that is under slab.Concrete slab still broken and needs repaired.
Location: Not Provided
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and ina sanitary condition?(|PK4[305)
Inspector:BARRYSTRATTUN Comments:Egress lights,fire extinguishers,fire doors,
front door threshold.
Location: Not Provided
OMERAL NOTES
~."."u or,ny `o,+o
Page sof4
+ . . `
BAnRYSTRATTUN 09/21/2023@y10:38 A[disconnect still hanging,lights not working and front landing condition.Still not
corrected. Back door nobuilding is missing door hardware.
mcxmPcCmmmuAnr
CONTACT SIGNATURE
Caliber Group |
edon:00/21/JU23@p1O:30 /� /�\��/L—
INSwECTmmumomArmRE
BARRvSTRATTON
Signed on:09/21/2U23@p1O:30 |
QUESTIONS ABOUT YOUR INSPECTION?
BARRYSTRATTUN
barry.strauon@water|oo'ia.org
(319)231'9147
pxnted onmm 10:40