Loading...
HomeMy WebLinkAbout1133 DIXON DR W 4 T INVOICE DATE DUE DATE INVOICE# TOTAL DUE 11/01/2023 12/10/2023 2024-00000072 $250.00 3 • �����,��iissrrisrrsrro i It r st•a ear�.ssr • ) v 0 0-(E—CCCC0075 Customer#: 24076 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HUNDRED TICKET VISION LLC 715 Mulberry St PO BOX 56 WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 1133 DIXON DR- 9-21-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24076 11/01/2023 12/10/2023 2024-00000072 $250.00 Less Prepayment $0.00 Total Due-* $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. .e.r \�' �� (�v� � `~'` WATERLOO &��@��� ����� ����� �J��m�n� �-�J�� RESCUE INSPECTION REPORT 112S-1133 DIXON DRIVE CONDOMINIUMS BLDG, 1133 DIXON DR, WATERLOO 1A S0701 DcrxuS _ Inspection Date:00/21/2023 | Inspection Type: Rental Inspection | Inspection Number: 10912 Sh'fc N/A i Station: N/A � Unit: N/A | Lead Inspector:BARRYSTRATT0N Other|nspectors' .N/A | Fee $350�0 � . STATUS CODE DESCRIPTION FAIL 1008.1 Means ofegress Illumination shall be provided in the means of egress in accordance with Section illumination. 1008.2. Under emergency power, means of egress illumination shall comply with Secc\on1O08.l Inspector: BARRYSTRATTOm Comments:Egress lighting does not work.Today's inspections lights still do not work. Location: Not Provided FAIL 1032.2 ReUabi|iry. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions nr impediments tofull instant use in the case nffire or other emergency where the building area served by the means of egress is Occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:BARRYSTRugTON Comments:Front door threshold is obstructing door from closing.Threshold is still not repaired. Rear door is missing door hardware. Location: Not Provided FAIL 603.2 Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other eqUipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not beused. Inspector:BARRYSTRAlTON Comments:AC disconnect box on East side ofbuilding is hanging by wires. Box needs secured to building.AC disconnect box still hanging from building. Box still hanging not secured to building Location: Not Provided '^""u on, op'z �:�� Page 1or4 STATUS CODE DESCRIPTION FAA 704.3-Opening protectives. Where openings are required to be protected, opening protectives shall be maintained self-closing or automatic-closing by smoke detection. Existing fusible-link- type automatic door-closing devices are permitted if the fusible link rating does not exceed 135°F(57°C). Inspector: BARRY STRATTON-Comments:Fire doors in open position. Fire doors still left in the open position on todays inspection,may require door closures installed on doors. Location: Not Provided FAIL 901.6-Inspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems, maintenance. fire-extinguishing systems, mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8 . Inspector:BARRY STRATTON-Comments:Alarm need maintenance and testing. Alarm testing still requires tested.Still not done. Location: Not Provided Printed on 09/21/2023 of.10:40 Page 2 of 4 ` S7mrmS CODE oeScnxmr/om FAIL 906.1 Vvhererequired. Pot-table fire extinguishers shall be installed in all of the following locations: 1.111 new and existing Group A` D' E' F, H' |./N' R,1' R-2' R~4 and S Occupancies. Exceptions: 1.1n Group R-2 Occupancies, pot-table fire extinguishers shall be required only in locations specified in Iterns 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having aminimum rating of1+\:1O'BI.2.|n Group EOccupancies, pot-table fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a pot-table fire extinguisher having a minimum rating ofZ-A:2U'B:C.3. In storage areas of Group 5 occupancies where forklift,powered industrial truck or powered can operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use ofvehide'mounred extinguishers shall be approved by the fire code official. 3.2. Each vehicle shall be equipped with a 10, pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on'sitetn replace adischarged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5. Inspections o[vehicle- mounted extinguishersshaUbeperformeddai|y.2.VVichin38feex(0144mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.1n areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of scruccuresunderconscrucrion. exceptGroupR'3occupancies' inaccordancewith Section3316.1. 5.VVhere required by the sections indicated in Table 0D6.1.6.Specia|' hazard areas, induding but not limited to laboratories, computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector: BARRv6TRATTON Comments:Fire Extinguishers need updated.(Z021). Fire extinguishers still out of date(2021). Location: Not Provided FAfL R4 Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(|Px4[382) Inspector: BAKRYSTR/QTON Comments:Front concrete slab atdnor. Busted concrete missing that is under slab.Concrete slab still broken and needs repaired. Location: Not Provided FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and ina sanitary condition?(|PK4[305) Inspector:BARRYSTRATTUN Comments:Egress lights,fire extinguishers,fire doors, front door threshold. Location: Not Provided OMERAL NOTES ~."."u or,ny `o,+o Page sof4 + . . ` BAnRYSTRATTUN 09/21/2023@y10:38 A[disconnect still hanging,lights not working and front landing condition.Still not corrected. Back door nobuilding is missing door hardware. mcxmPcCmmmuAnr CONTACT SIGNATURE Caliber Group | edon:00/21/JU23@p1O:30 /� /�\��/L— INSwECTmmumomArmRE BARRvSTRATTON Signed on:09/21/2U23@p1O:30 | QUESTIONS ABOUT YOUR INSPECTION? BARRYSTRATTUN barry.strauon@water|oo'ia.org (319)231'9147 pxnted onmm 10:40 Page 4o,4