Loading...
HomeMy WebLinkAbout1938 FLOWER ST #2 W A. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 11/01/2023 12/10/2023 2024-00000076 $250.00 .1!/I/1►` 4 4 f 4''tt� r r•r.r+rr - 0 Customer#: 10811 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DOMINIC TANGEN 715 Mulberry St 2501 SCENIC DR WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1738 FLOWER ST-#2 9-14-23 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price J REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10811 11/01/2023 12/10/2023 2024-00000076 $250.00 Less Prepayment $0.00 Total Due—+ $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. . c‘\\ WATERLOO FIRE RESCUE _ \L) .. INSPECTION REPORT � 4) DOMINIC TANGEN RENTAL 8-FLEX, 1738 FLOWER ST, WATERLOO IA 5070 4... 424;;; '6 DETAILS Inspection Date:09/14/2023 I Inspection Type: Rental Inspection I Inspection Number: 10871 I S ift:, /A I Station: N/A Unit: N/A I Lead Inspector: BARRY STRATTON 1 Other Inspectors: N/A j Fee:$250.00 t /41, 1,...,3.2 STATUS CODE DESCRIPTION FAIL 1013.3-Illumination Exit signs shall be internally or externally illuminated. Exception:Tactile signs required by Section 1013.4 need not be provided with illumination. Inspector: BARRY STRATTON-Comments: Egress/exit lights Location: Interior of building FAIL 1025.5- Illumination Where photoluminescent exit path markings are installed,they shall be provided with not less than 1 footcandle(11 lux)of illumination for not less than 60 minutes prior to periods when the building is occupied and continuously during the building occupancy. Inspector: BARRY STRATTON-Comments: None Location: Not Provided FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments:Outlets missing and wire being scrapped from building Location:All apartments. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Several electrical hazards exist throughout building. Location: Not Provided Page 1 of 5 ` . S[wrmm CODE oeSCn/*runm FAIL 70I2 Openingprotecives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening prorpoives shall follow tile requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector:8ARRYSTRATTUN Comments:Alarm testing and maintenance hassui||nnt been done. Location: Not Provided FAIL 901.6 inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust maintenance systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequiredfire protection systems and equipment shall be inspected,tested and maintained or removed. Inspector: BARRYSTRATTON Comments:Alarm Location: Not Provided FAIL 901.6.1 Standards Fire protection systems shall be inspected'tested and maintained in accordance with the referenced standards listed inTable. Inspector: BARRYSTRATTON Comments:None Location: Not Provided FAIL 9061 Vvhererequired Pot-table fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A. 8'E. F, H. |' N1' R'1, R'2'R'4and Soccupancies. Exception: in Group R,Zoccupancies. portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1'A: 1O'B:C.2.Within]U feet(9144 nnm) of commercial cooking equipment.I In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas' including but not limited tolaboratories,computer rooms and generator rooms' where required by the fire code official. Inspector: BARRvSTRATTUN Comments:None Location: NocProvided vr;nteoon 09'014/mc»�n,m Page zo,5 STATUS CODE DESCRIPTION, FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Detectors missing throughout building and all apartments. Location:Interior of Building FAIL R2- Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:All units are uninhabitable. Building does not meet fire safety and rental requirements. Location: Not Provided FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments:Apartments 1-8 Location: Not Provided FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:Debris Location: Not Provided FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Windows, doors, electrical Location:Not Provided FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:All units 1-8 unfit to occupy Location:Not Provided P;intee :. 4,2023,a.11:49 Page 3 of 5 STATUS CODE oEuCm/PmOm ' FAIL R6^^ Interior Structure- vNere any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:8ARRYSTR/QTON Comments:None Location: Not Provided FAIL R6.B. Residencia| Hearing Are dwellings provided with heating facilities capable of maintaining a room temperature of68F?(|PK4C602.2) Inspector:QARRYSTRATTON Comments:None Location: Not Provided FAIL RG.[. Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(|PK4[6O3.1) Inspector: BARRvITRATTOm [omnnencs:None Location: Not Provided GENERAL NOTES BARRYSTRATTON 09/14/2023@11:47 111.2 Closing of vacant structures. if the structure is vacant and unfit for human habitation and occupancy,and is not in danger of structural collapse,the code official is authorized to post a placard of condemnation on the premises and order the structure closed up so as not to be an attractive nuisance. Upon failure of the owner or owner's authorized agent to close up the premises within the time specified in the order,the code official shall cause the premises to be closed and secured through any available public agency or by contract or arrangement by private persons and the cost thereof shall be charged against the real estate upon which the souccure is located and shall be a lien upon such real estate and shall be collected by any other legal resource. BARnvSTRA7TON 09/14/2023@11:47 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official.Any person who shall occupy a placarded premises or shall operate placarded equipment,and any owner or owner's authorized agent who shall let anyone occupy a placarded premises or operate placarded equipment shall be liable for the penalties provided by this code. BARnvSTnA7TON 09/14/2023@11:47 9-749'75: 2O23 Rental Registration is needed.Still not registered mrxmSpECr/OmuArE 1O/11/2O23 Printed onmx`^/2mo Cc.``"m Page 4oyn CONTACT SIGNATURE . • Dominic Tangen L7A1\\ Signed on:09/14/2023 @ 11:48 INSPECTOR SIGNATURE BARRY STRATTON —71 Signed on:09/14/2023 @ 11:48 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Page 5 of 5