RENTAL INSPECTION - 1930 HAWTHORNE AVE-9-29-23 FOR BILLING INQUIRY: (319)291-4323
lDescription I Total Price j
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23001 11/01/2023 12/10/2023 2024-00000080 $150.00
Less Prepayment $0.00
Total Due-* $150.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WA TERL a Q FIRE RESCUE C)sfUer
INSPECTION REPORT `.
TZ;
1930 HAWTHORNE AVE, WATERLOO IA 50702 \ VV
DETAILS
Inspection Date:09/29/2023 ► Inspection Type: Rental Inspection I Inspection Number: 10112 1 Shift: N/A 1 Station: N/A
Unit: N/A 1 Lead Inspector:BARRY STRATTON 1 Other Inspectors: N/A ; Fee:$150.00
STATUS CODE DESCRIPTION
FAIL 1003.6- Means of egress The path of egress travel along a means of egress shall not be interrupted by a
continuity building element other than a means of egress component as specified in this
chapter.Obstructions shall not be placed in the minimum width or required capacity
of a means of egress component except projections permitted by this chapter.The
minimum width or required capacity of a means of egress system shall not be
diminished along the path of egress travel.
Inspector: BARRY STRATTON-Comments:Items stored un hallway upstairs. Need to
maintain a clear egress path with no obstructions.
Location: Hallways
FAIL 1010.1.9.4-Bolt locks Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1.On
doors not required for egress in individual dwelling units or sleeping units.2.Where
a pair of doors serves a storage or equipment room, manually operated edge-or
surface-mounted bolts are permitted on the inactive leaf. 3.Where a pair of doors
serves an occupant load of less than 50 persons in a Group B, F or S occupancy,
manually operated edge-or surface-mounted bolts are permitted on the inactive
leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating
hardware.4.Where a pair of doors serves a Group B, F or S occupancy,manually
operated edge-or surface-mounted bolts are permitted on the inactive leaf provided
such inactive leaf is not needed to meet egress capacity requirements and the
building is equipped throughout with an automatic sprinkler system in accordance
with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or
similar operating hardware. 5.Where a pair of doors serves patient care rooms in
Group 1-2 occupancies, self-latching edge-or surface-mounted bolts are permitted on
the inactive leaf provided that the inactive leaf is not needed to meet egress capacity
requirements and the inactive leaf shall not contain doorknobs,panic bars or similar
operating hardware.
Inspector: BARRY STRATTON-Comments: Padlock hasp on door needs removed.
Location: Upstairs apartment
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices, appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Extension cords need removed. Unit 5
Location: Not Provided
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall he required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C. 2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. in areas where flammable or combustible
liquids are stored, used or dispensed.4. On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5.
Where required by the sections indicated in Table 906.1.6. Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:Hallway extinguisher outdated(2001)
Location:Not Provided
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Units 1-5 and common hallway upstairs
and main level.Smoke detector missing in unit 5
Location: Not Provided
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:Unit#1
Location: Not Provided
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Peeling paint needs corrected. Unit 1 floor
needs tack strip removed. Floors need to be capable of being cleaned and sanitary.
Location: Not Provided
Prince
Page 2 of 3
•
REINSPECTION DATE
10/26/2023
CONTACT SIGNATURE
Dan Reyerson ( V\
Signed on:09/29/2023 @ 09:38
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:09/29/2023 @ 09:38
QUESTIONS AIOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed on O929i2C :3 1•!
Page 3 of 3