Loading...
HomeMy WebLinkAbout212 IRVING ST 0W 4 T INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 11/01/2023 12/10/2023 2024-00000083 $250.00 w...�.r.r.. ,� s Ivil`' Customer#: 24033 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IA INVESTMENT PROPERTY 715 Mulberry St 5001 1ST AVE SE SUITE 105,221 WATERLOO, IA 50703 CEDAR RAPIDS, IA 52402 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 212 IRVING ST - 10-2-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24033 11/01/2023 12/10/2023 2024-00000083 $250.00 Less Prepayment $0.00 Total Due ---> $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE r 1 INSPECTION REPORT � IA INVESTMENT PROPERTIES LLC, 212 IRVING ST, WATERLOO IA 50703 ^ N DETAILS Inspection Date: 10/02/2023 I Inspection Type: Rental Inspection ; Inspection Number: 10986 I Shift: N/A Station: N/A j Unit: N/A j Lead Inspector:BARRY STRATTON j Other Inspectors: N/A Fee:$250.00 rd ; V STATUS CODE DESCRIPTION FAIL 1010.1.9- Door operations Except as specifically permitted by this section, egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRY STRATTON-Comments:Front door needs replaced. Security hardware damaged and does not work. Location: Not Provided FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following: Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector: BARRY STRATTON-Comments:Windows broken Location: Not Provided FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Outlets covers missing,outlets pulling out of walls Location: Not Provided Printed on 10/02/2023;c 07:15 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4. On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6. Special-hazard areas, including hut not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: None Location: Not Provided FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA.72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors needed in each bedroom and in basement also outside of bedrooms. Location: Not Provided FAIL R1 -Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure?(IPMC 108.1.1) Inspector: BARRY STRATTON-Comments: Floors and stair handrail, electric system Location: Not Provided FAIL R3- Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments: Mold and structural issues with floors Location: Not Provided FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector: BARRY STRATTON-Comments: Roof leaks,front porch and stairs need replaced. Location: Not Provided FAIL P6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound, and in a sanitary condition?(IPMC 305) P,-rated on 10,,02i=._: 3 _16 Page 2 of 4 • STATUS CODE DESCRIPTION Inspector: BARRY STRATTON-Comments: Roof Leak,ceilings in bedrooms and dining room damaged from water leak,floors damaged and need replaced throughout house,toilet needs re-set on floor on 1st floor and 2nd floor toilet does not work, bath tub on 1st has leak that runs on floor,and sink leaks. Kitchen sink does not drain, peeling paint throughout house, door hardware missing on doors,broken windows need repaired. Handrail and balusters need replaced going upstairs. Mice infestation. Location: Not Provided FAIL R6.A.- Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments:Floors unstable, porch floor and stairs unstable Location: Not Provided FAIL R6.B.- Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector: BARRY STRATTON-Comments:Register covers missing and some not attached,gravity ducts not working and full of debris. Location: Not Provided GENERAL NOTES BARRY STRATTON- 10/02/2023 @ 07:15 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official.Any person who shall occupy a placarded premises or shall operate placarded equipment,and any owner or owner's authorized agent who shall let anyone occupy a placarded premises or operate placarded equipment shall be liable for the penalties provided by this code. BARRY STRATTON - 10/02/2023 @ 07:15 111.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe, unlawful or, because of the degree to which the structure is in disrepair or lacks maintenance, is insanitary, vermin or rat infested,contains filth and contamination,or lacks ventilation, illumination,sanitary or heating facilities or other essential equipment required by this code, or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. Listed address on today's inspection was unsecure and appears to to have vagrants living inside. REINSPECTION DATE 10/30/2023 Printed on 10102/2023-07.'£ Page 3 of 4 CONTACT SIGNATURE Joyce Wood EAL Signed on: 10/02/2023 @ 07:15 INSPECTOR SIGNATURE BARRY STRATTON Signed on:10/02/2023 @ 07:15 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 ,,ted 10'02,2023 CEI:07:15 Page 4 of 4