RENTAL INSPECTION- 620 KEYSTONE ST- 10-17-23 FOR BILLING INQUIRY: (319)291-4323
LDescription I Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24118 11/01/2023 12/10/2023 2024-00000087 $250.00
Less Prepayment $0.00
Total Due $250.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE vE.Fi
INSPECTION REPORT ►`
DARRELL HUGGINS SINGLE FAMILY RENTAL, 620 KEYSTONE ST, WATERLOO IA 50703
DETAILSCI100
Inspection Date: 10/17/2023 I Inspection Type: Rental Inspection I Inspection Number: 11029 I Shift: N/A I Station: N/A I
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A j Fee:$250.00
7,05,61
STATUS CODE DESE`R/PTION
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector: BARRY STRATTON-Comments: Kitchen ceiling fan not working on switch.
Outlets missing covers,outlets not working and outlets have tension strength issues.
Need 3'ft.clearance to electric panel.Vanity light in bathroom has a short in socket.
Handrail needs to be installed to basement.Current handrail is not attached. Carpet
in hallway is bunched up and could cause trip hazards. Need transition strips in place
from carpet to other rooms.
Location: Not Provided
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72.
alarms.
Inspector: BARRY STRATTON-Comments: Need smoke detectors installed in each
bedroom and outside bedrooms.
Location:Not Provided
FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6. Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:Need CO detector installed in vicinity of the
bedrooms.
Location:Not Provided
FAIL R6.C.-Mechanical Egiup -lent Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
P"riie0 Or -- -
Page 1 of 2
•
STATUS CODE DESCRIPTION
Inspector: BARRY STRATTON-Comments:Sump pump needs disconnected from
sanitary sewer.Also sump pump float does not work. Pit needs to be manually
drained.
Location: Not Provided
FAIL R6.D. -Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or a receptacle with a GFCI. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFCI
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector: BARRY STRATTON-Comments:Outlets covers missing.
Location: Not Provided
GENERAL NOTES
BARRY STRATTON-10/17/2023 @ 12:07 IFC 906:Need fire extinguisher in unit.
REINSPECTION DATE
11/14/2023
CONTACT SIGNATURE
Darrell Huggins
Signed on:10/17/2023 @ 12:11 /\\I\IL._._
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:10/17/2023 @ 12:11