Loading...
HomeMy WebLinkAbout933 KINGSLEY AVE O W A� INVOICE DATE DUE DATE INVOICE# TOTAL DUE t 0 11/01/2023 12/10/2023 2024-00000088 $250.00 `'�/��I Rsr rrifrrir� 0 0 Customer#: 4967 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MICHAEL TAYLOR 715 Mulberry St 322 RAE DR WATERLOO, IA 50703 EVANSDALE, IA 50707 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION - 933 KINGSLEY AVE- 9-21-23 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price J REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4967 11/01/2023 12/10/2023 2024-00000088 $250.00 Less Prepayment $0.00 Total Due -* $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE 4,P., INSPECTION REPORT ..AMICHAEL TAYLOR SINGLE FAMILY RENTAL, 933 KINGSLEY AVE, WATERLOO IA 50701 `' DETAILS Inspection Date:09/21/2023 1 Inspection Type:Rental Inspection 1 Inspection Number: 10913 ! Shift: N/A I Station: N/A Unit: N/A 1 Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 'Wei 4-3715, STATUS CODE DESCRIPTION FAIL 1031.1 -General. Emergency escape and rescue openings shall comply with the requirements of this section. Inspector:BARRY STRATTON-Comments:No egress window in basement. Location: Not Provided FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector:BARRY STRATTON-Comments:Light missing in living room,(possible electrical fire in fixture), missing switch in living room.ground lug on waterline in basement needs secured,extension cords in use need removed,missing covers on electric boxes in basement,light fixture not attached to box in basement,bedroom outlet pulling out of wall. Need plates on all switches and outlets. Location: Not Provided 1 Pslnted on 09,21i2023.c 10:35 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 906.1 -Where required. Portable fire extinguishers shall be installed in all of the following locations: 1.1n new and existing Group A,B, E, F, H, I, M, R-1,R-2,R-4 and S occupancies. Exceptions: 1.1n Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.€n Group E occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each classroom is provided with a portable fire extinguisher having a minimum rating of 2-A:20-B:C.3. In storage areas of Group S occupancies where forklift,powered industrial truck or powered cart operators are the primary occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall be approved by the fire code official.3.2.Each vehicle shall be equipped with a 10- pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket approved by the extinguisher manufacturer or the fire code official for vehicular use. 3.3. Not less than two spare extinguishers of equal or greater rating shall be available on-site to replace a discharged extinguisher.3.4.Vehicle operators shall be trained in the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle- mounted extinguishers shall be performed daily.2.Within 30 feet(9144 mm)distance of travel from commercial cooking equipment and from domestic cooking equipment in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction, except Group R-3 occupancies, in accordance with Section 3316.1.5.Where required by the sections indicated in Table 906.1.6.Special- hazard areas, including but not limited to laboratories,computer rooms and generator rooms,where required by the fire code official. Exception: Portable fire extinguishers are not required at normally unmanned Group U occupancy buildings or structures where a portable fire extinguisher suitable to the hazard of the location is provided on the vehicle of visiting personnel. Inspector:BARRY STRATTON-Comments:None Location: Not Provided FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NFPA 72. alarms. Inspector:BARRY STRATTON-Comments:Detectors all need to be in working condition.Need detector in basement. Location: Not Provided FAIL 915.1 -General. Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6,Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector;BARRY STRATTON-Comments:Need to be in working condition Location: Not Provided Printed or,09/21/2023 3 10:35 Page 2 of 4 STATUS CODE DESCRIPTION FAI L R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:Ground heaving from water. Possible broken service line. Front steps tipping out away from house.Sidewalk is heaved. Front steps still not corrected. Location:Not Provided FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Toilet needs re-set on floor with new wax ring,tub clean out door in bedroom needs approved door. Dishwasher leaking,no egress window in basement,(bed in basement), Foundation is leaking,drain in basement does not drain,shower valve in basement leaks, High water bills,water service is leaking.Sewer pipe in basement leaking. Basement window by laundry leak when raining. Drain in basement is backed up and not draining. Location: Not Provided FAIL R6.C.- Mechanical Egiuprment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments:Intermittent hot water. Location: Not Provided GENERAL NOTES BARRY STRATTON-09/21/2023 @ 10:34 9-7-7: INSPECTIONS REQUIRED:A.Rental Properties: Regular inspection on all residential rental property,including mobile homes,shall be made once every three(3) years for compliance with the building code, property maintenance code, other applicable codes,and this chapter.In addition to said codes and this chapter,the housing quality standards promulgated by the United States Department of Housing and Urban Development for use in assisted housing programs shall govern to the extent not superseded by more stringent requirements of said codes and this chapter. Inspections of all properties shall also be made at any time upon receipt of a complaint or request by a tenant or owner.Any rental structure receiving two(2)complaints regarding substantiated violations during any twelve(12)month period shall be put on an annual inspection schedule for three(3)years following the last substantiated complaint.C.Certificate Of Inspection: 1. No person shall rent, lease or cause to be occupied any rental unit that does not possess a certificate of inspection issued under this code.Any landlord or responsible local agent registering a rental unit for the first time must have a rental inspection completed prior to renting a rental unit and prior to receiving a rental unit permit. Printed on 09f2 __ --c Page 3 of 4 3 - GENERAL NOTES BARRY STRATTON-09/21/2023 @ 10:34 New tenants at listed address without inspection. Contact city inspector to schedule a re-inspection. REINSPECTION DATE 10/18/2023 CONTACT SIGNATURE Michael Taylor Signed on:09/21/2023 @ 10:35 INSPECTOR SIGNATURE BARRY STRATTON Signed on:09/21/2023 @ 10:35 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 "tec D;: 2:23 15 Page 4 of 4