Loading...
HomeMy WebLinkAbout1202 W 2ND ST W q 1. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 , tr e 11/01/2023 12/10/2023 2024-00000094 $250.00 O tt1��'���y�;ss ssi�ri. • e i irr Customer#: 23001 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable QUALITY CONCRETE CONTRUCTION (RENTAL) 715 Mulberry St 1930 HAWTHORNE AVE#1 WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1202 W 2ND ST-9-28-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23001 11/01/2023 12/10/2023 2024-00000094 $250.00 Less Prepayment $0.00 Total Due—> $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. V 1 �pYLHlfYn WATERLOO FIRE RESCUE INSPECTION REPORT , ,4.*',' QUALITY CONCRETE MULTI-RESIDENTIAL RENTALS, 1202 ill!2ND ST, WATERLOO IA 50701 -,RE"`' DETAILS Inspection Date:09/28/2023 ( Inspection Type: Rental Inspection l Inspection Number: 10964 f Shift: N/A ; Station: N/A Unit: N/A I Lead Inspector:BARRY STRATTON 1 Other Inspectors: N/A ; Fee:$250.00 „d //k, oeC— ''1 h STATUS CODE DESCRIPTION FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section.Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats,tables,furnishings,displays and similar fixtures or equipment.The minimum width or required capacity of aisles shall be unobstructed. Exception: Encroachments complying with Section 1005.7. Inspector: BA.RRY STRATTON-Comments:None Location: Not Provided FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector: BARRY STRATTON-Comments:Doors&Jambs Location: Not Provided FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments: Missing globes, electric panel needs access to panel,junk appliances in basement blocking egress path Location: Not Provided Printed on D9;2?12-2'- -,_ Page 1 of 5 • STATUS CODE DESCRIPTION FAIL 703,1 - Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops, shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated.Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector: BARRY STRATTON-Comments:Water damage to walls and floors. Damaged material needs removed and replaced. Location: Not Provided FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E,F, H, I, M,R-1,R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments:None Location: Not Provided FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:None Location: Not Provided Printed on 09=: Page 2 of 5 STATUS CODE DESCRIPTION FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6. Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments: None Location: Not Provided FAIL R1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure?(IPMC 108.1.1) Inspector: BARRY STRATTON-Comments: None Location: Not Provided FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments: None Location: Not Provided FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Deck to entrance door and handrail on deck all need replaced Location: Not Provided FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments: Entry door needs replaced.jamb and door are broken.Broken windows need replaced. Egress path is blocked in kitchen because refrigerator is blocking path.Ceiling in living room has collapsed. Bath sink is not secured to wall in bathroom. Sewer leak in basement needs repaired by licensed professional.Screen door does not have any door hardware. Back door to 1202 did not function because tenant advised it is broken. Security hardware to keep door secured in jamb is broken and jamb not capable to keep door secured and weather tight. Missing glass on porch windows Location: Not Provided FAIL R6.A.- Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments:Mold&water damage Page 3 of 5 STATUS CODE DESCRIPTION. , . Location: Not Provided FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments: Maintenance to furnace is needed. Location: Not Provided GENERAL NOTES BARRY STRATTON-09/28/2023 @ 10:15 Corrections still not complete BARRY STRATTON-09/28/2023 @ 10:15 109.4 Violation penalties.Any person who shall violate a provision of this code,or fail to comply therewith, or with any of the requirements thereof, shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense. BARRY STRATTON-09/28/2023 @ 10:15 109.5 Abatement of violation.The imposition of the penalties herein prescribed shall not preclude the legal officer of the jurisdiction from instituting appropriate action to restrain,correct or abate a violation,or to prevent illegal occupancy of a building, structure or premises, or to stop an illegal act,conduct, business or utilization of the building,structure or premises. BARRY STRATTON-09/28/2023 @ 10:15 9-7-6:DENIAL,SUSPENSION, REVOCATION OR NONRENEWAL:D.Rent Abatement: No rent may be collected for any rental unit not covered by a valid, current rental unit permit.The licensing officer may order rent abated when it is determined that the owner has,after issuance of a notice of violation of this chapter:2.Failed to remedy a condition that poses a substantial risk to the health or safety of the tenant, unless the tenant's or the tenant's guests acts or omissions caused said condition. REINSPECTION DATE 10/26/2023 CONTACT SIGNATURE Quality Concrete Construction L-N'\SL Signed on:09/28/2023 @ 10:15 PCMtEC -- _ '0:5 Page 4 of 5 INSPECTOR SIGNATURE I 1 BARRY STRATTON Signed on:09/28/2023 @ 10:15 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Page 5 of 5