HomeMy WebLinkAbout1738 FLOWER ST #2 WA T INVOICE DATE DUE DATE INVOICE# TOTAL DUE
'' 12/06/2023 01/10/2024 2024-00000122 $250.00
,,,,,,,,,,
Customer#: 10811 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
DOMINIC TANGEN 715 Mulberry St
2501 SCENIC DR WATERLOO, IA 50703
CEDAR FALLS, IA 50613
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION - 1738 FLOWER ST#2 - 12-5-23 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
10811 12/06/2023 01/10/2024 2024-00000122 $250.00
Less Prepayment $0.00
Total Due-* $250.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
• 1C /J
WATERLOO FIRE RESCUE 441 F.!0
INSPECTION REPORT
DOMINIC TANGEN RENTAL 8-PLEX, 1738 FLOWER ST, WATERLOO IA SOTQ 2 0
DETAILS
Inspection Date: 12/05/2023 1 Inspection Type: Rental Inspection 1 Inspection Number: 11376 1 Shift: N/A 1 Station: N/A 1
Unit: N/A 1 Lead Inspector:BARRY STRATTON 1 Other Inspectors: N/A 1 Fee:$250.00
(r -fr OSP
STATUS CODE DESCRIPTION
FAIL 1013.3- Illumination Exit signs shall be internally or externally illuminated. Exception:Tactile signs required
by Section 1013.4 need not be provided with illumination.
Inspector: BARRY STRATTON-Comments:Egress/exit lights
Location: Interior of building
FAIL 1025.5- Illumination Where photoluminescent exit path markings are installed,they shall be provided with
not less than 1 footcandle(11 lux)of illumination for not less than 60 minutes prior to
periods when the building is occupied and continuously during the building
occupancy.
Inspector:BARRY STRATTON-Comments:None
Location: Not Provided
FAIL 1031,2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:BARRY STRATTON-Comments:Outlets missing and wire being scrapped
from building
Location:All apartments.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Several electrical hazards exist throughout
building.
Location: Not Provided
Printed on 1210512023 06.44
Page 1 of 5
STATUS CODE DESCRIPTION
FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance of opening protectives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged.Fire door assemblies shall not be modified.
Inspector: BARRY STRATTON-Comments:Alarm testing and maintenance has still not
been done.
Location: Not Provided
FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector: BARRY STRATTON-Comments:Alarm
Location: Not Provided
FAIL 901.6.1 - Standards Fire protection systems shall be inspected,tested and maintained in accordance with
the referenced standards listed in Table.
Inspector: BARRY STRATTON-Comments:None
Location: Not Provided
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B, E, F, H, I, M, R-1, R-2,R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored,used or dispensed.4. On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:None
Location: Not Provided
Printed on 1 2/0 51202 3(c.06:44
Page 2 of 5
STATUS CODE DESCRIPTION
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Detectors missing throughout building and
all apartments.
Location: Interior of Building
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator, moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:All units are uninhabitable. Building does
not meet fire safety and rental requirements.
Location: Not Provided
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:Apartments 1-8
Location:Not Provided
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector: BARRY STRATTON-Comments: Debris
Location: Not Provided
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Windows,doors, electrical
Location: Not Provided
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been ria.intained in good
repair,structurally sound, and in a sanitary condition?(IPMC DD5)
Inspector: BARRY STRATTON-Comments:All units 1-8 unfit to occupy
Location: Not Provided
Printed on 12/05/2023 06:44
Page 3 of 5
STATUS CODE DESCRIPTION
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:None
Location:Not Provided
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:None
Location: Not Provided
FAIL R6.C.-Mechanical Egiupri lent Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:None
Location: Not Provided
GENERAL NOTES
BARRY STRATTON-12/05/2023 @ 06:41 111.2 Closing of vacant structures. If the structure is vacant and unfit for human
habitation and occupancy,and is not in danger of structural collapse,the code official
is authorized to post a placard of condemnation on the premises and order the
structure closed up so as not to be an attractive nuisance. Upon failure of the owner
or owner's authorized agent to close up the premises within the time specified in the
order,the code official shall cause the premises to be closed and secured through any
available public agency or by contract or arrangement by private persons and the cost
thereof shall be charged against the real estate upon which the structure is located
and shall be a lien upon such real estate and shall be collected by any other legal
resource.
BARRY STRATTON-12/05/2023 @ 06:41 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the
code official shall be vacated as ordered by the code official.Any person who shall
occupy a placarded premises or shall operate placarded equipment,and any owner or
owner's authorized agent who shall let anyone occupy a placarded premises or
operate placarded equipment shall be liable for the penalties provided by this code.
BARRY STRATTON-12/05/2023 a 06:41 9-7-4 9-7-5:2023 Rental Registration is needed.Still not registered
REINSPECTION DATE
01/02.`2024
Printed do 12/0512023 06:44