RENTAL INSPECTION- 933 KINGSLEY AVE- 8-22-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price]
REINSPECTION FEE 3RD � ?
2� $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# _ CHARGES
4967 08/28/2023 09/30/2023 2024-00000055 $250.00
Less Prepayment $0.00
Total Due— $250.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
` .
WATERLOO 0��������������� FiRE RESCUE
INSPECTION REPORT
MICHAEL TAYLOR SINGLE FAMILY RENTAL, 933 KINGSLEYAVE, WATERLOO JA 50701
Df TAILS
Inspection Date:08/22/2023 | Inspection Type: Rental Inspection I Inspection Number: 10703 1 Shift: N/A Station: N/A (
Unit: N/A | Lead|nspeccoc8ARRYSTKATTON | Other Inspectors: Mx\ I Fee:$250.80
S TAVUS CODE DmmCRxPTxOm,
FAIL 1031.1 Genet-al. Emergency escape and rescue openings shall comply with the requirements of this
section.
Inspector: 8ARRvSTRxTTOm Comments:No egress window inbasement.
Location: Not Provided
FAIL 603.2 Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not beused.
Inspector: BARRYSTRATTON Comments:Light missing in living room,(possible
electrical fire in fixture)' missing switch in living room,ground lug on waterline in
basement needs secured,extension cords in use need removed,missing covers on
electric boxes in basement, light fixture not attached to box in basement, bedroorn
outlet pulling out of wall. Need plates on all switches and outlets.
Location: Not Provided
p,'"°o or,oo/zz/2oz3 ,o,az
Page of
STATUS CODE mESCm/Pmmm
FAIL 9061 Where required. Portable fire extinguishers shall be installed in all oy the following locations: 1]nnew
and existing Group A`B'�F,H.|.M, R'1'R-2, R~4 and S occupancies.Exceptions:1.|n
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Iterns 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minit-num rating of 1-A:10-B:C.2.1n Group E occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of2+\:20'B:[.3. In storage areas of Group 5 occupancies where
forklift,powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2. Each vehicle shall be equipped with a10-
pound,40A:80B:C extinguisher affixed to the vehicle using a mounting bracket
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on'siteto replace a discharged extinguisher.3.4.Vehic|e operators shall be trained in
the proper operation,use and inspection of extinguishers.3.5. Inspections of vehicle-
mounted exdnguisherssha||beperformeddai|y.2.VVichin3Ufeer(0144mmn)distance
oft/'ave|fionncommerda|cookingequipnnentandfromdomesticconkingequipment
in Group|'1; |'2'Condition 1;and R'2 college dormitory occupancies.3.|n areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
structures under construction,except Group R-3 occupancies, in accordance with
Section 3316.1.5.VVhere required by the sections indicated in Table 006.1.6.Specia|
hazardareas'inc|udingbutnot|imitedco|aborarories'computerrnomsand
generator rooms,where required by the fire code official. Exception:Pot-table fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a portable fire extinguisher suitable to the hazard of the location
is provided oo the vehicle of visiting personnel.
Inspector:BARRYSTRATT0w Comments:None
Location: Not Provided
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
rnu|tip\e'stadonsmoke installed in accordance with Sections 8U7.2.11.1 through QU7.3.11.7and NFPA72.
alarms.
Inspector:8ARRYSTR/QTON Comments:Detectors all need tobeinworking
condition.Need detector inbasement.
Location: Not Provided
FAIL 915.1 General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 015.1.1 through 915.6.Cat-bon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY5TR/QTUN Comments:Need tobpin working condition
Location: Not Provided
Printed""oo/z2/zoz3�1'`uaz
Page oor4
' -
STATUS CODE ' DESCRIPTION
FAIL R4 Exterior Property Areas |s the exterior property area maintained inadear\safe and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(|PM[382
Inspector: 8ARRv5TRATTOm Comments:Ground heaving from water. Possible
broken service line. Front steps tipping our away from house. Sidewalk is heaved.
Front steps still not corrected.
Location: Not Provided
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair, structurally Sound,and in a sanitary condition?(|PM[305)
Inspector: 8ARKYSTRATTOm Comments:Toilet needs re-set on floor with new wax
ring,tub clean out door in bedroom needs approved door. Dishwasher leaking, no
egress window inbasemenc(bed inbasemen¢ Foundation is leaking,drain in
basement does not drain'shower valve in basement|eaks. High water bills,water
service is leaking.Sewer pipe in basement leaking. Basement window by laundry leak
when raining.
Location: Not Provided
FAIL R5.[. Mechanical Eqiupment Are mechanical appliances properly installed and maintained it)good working
condition?(|PK4[6O3.1)
Inspector:8ARRYSTRATTON Comments: intermittent hot water.
Location: Not Provided
GENERAL NOTES
BAKRvSTRATTON 08/22/2023@ 10:30 Q'77: INSPECTIONS REQU|RED:A. Rental Properties: Regular inspection onall
residential rental property,including mobile homes'shall be made once every chree(])
years for compliance with the building code, property maintenance code'other
applicable codes,and this chapter. In addition to said codes and this chapter,the
housing cluality standards promulgated by the United States Department of Housing
and Urban Development fOr use in assisted housing programs shall govern to the
extent not superseded by more stringent requirements of said codes and this chapter.
inspections of all properties shall also be made at any time upon receipt of a complaint
or request by a tenant or owner.Any rental structure receiving cwo(2)complaints
regarding substantiated violations during any twelve(112)month period shall be put on
an annual inspection schedule for three(3)years following the last substantiated
complaint. C.Certificate Of inspection: 1.No pet-son shall rent, lease or cause to be
occupied any rental unit that does not possess a certificate of inspection issued under
this code.Any landlord or responsible local agent registering a rental unit for the first
time must have e rental inspection completed prior to renting rental unit and prior
to receiving a rental unit permit.
r,.".ea or.or.DZY'22,2oza�,usz
Page uur*
. f
GENERAL NOTES
BARRY STRATTON-08/22/2023 @ 10:30 New tenants at listed address without inspection. Contact city inspector to schedule a
re-inspection.
REINSPECTION DATE
09/22/2023
CONTACT SIGNATURE
Michael Taylor
Signed on:08/22/2023 @ 10:31 LII\NI—\\ML
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:08/22/2023 @ 10:31