HomeMy WebLinkAbout803 DENA ST OF W q TF INVOICE DATE DUE DATE INVOICE it TOTAL DUE
,� ��- 5�-e 08/28/2023 09/30/2023 2024-00000054 $150.00
v 4 o
O
4.
ds i v t l'�
Customer#: 24117 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
KO OHN 715 Mulberry St
122 PARK LN WATERLOO, IA 50703
WATERLOO, IA 50702
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION- 803 DENA ST- 8-14-23 FOR BILLING INQUIRY: (319)291-4323
[Description I Total Price j
REINSPECTION FEE 2ND $150.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24117 08/28/2023 09/30/2023 2024-00000054 $150.00
Less Prepayment $0.00
Total Due —> $150.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
. ^
WATERLOO \
0�N�������������� �-�N��� ������������ \ \ l
INSPECTION REPORT
KO OHN SINGLE FAMILY RENTAL,803 DENA ST,WA TEJ&OO JA S0702
mEnouS
Inspection Date:O8/14/2O23 1 Inspection Type: Rental Inspection 1 Inspection Number: 10620 | Shift: N/A | Station: N/A �
Unit: N/A \ Lead Inspector:BARRYSTRATTON Other Inspectors: N/A \ Fee:$150.00
STATUS CODE DEmCANnTyOuK
FAIL 1818.1 General, Aisles and aisle accesswaysserving asa portion oy the exit access in the means of
egress system shall comply with the requirements of this section.Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats,tables,furnishings,displays and similar fixtures or equipment.The
minimum width or required capacity of aisles shall be unobstructed.Exception:
Encroachments complying with Section 1nO5.7.
Inspector:8ARRYSTRATT0N Comments:Front egress door isblocked.
Location: Front door
FAIL 1031.1 General. Emergency escape and rescue openings shall comply with the requirements of this
section.
Inspector:BARRYSTRATT0N Comments:Need egress window inbasement
Location: Basement
FAIL 683.2 Abatement of unsafe Identified electrical hazards shall be abated. identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought co the attention of the responsible code offida|.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not beused.
Inspector:BARRvSTRATTON Comments:Outlet covers missing. Multi Adapter in use
in kitchen needs rernoved. Extension cord used that has washer and dryer plugged
into. Romexvires in basement not stapled correctly.
Location: Basement/Kitchen
prin°v""mv`4zz02,opup48
. .
STATUS CODE ` DESCRIPTION '
FAIL y06.1 'Where required. Portable fire extinguishers shall be installed in all of the following locations., 1.1n new
and existing Group A,8` �F, H. |.M. R,1. K-2' R-4 and 5 Occupancies. Exceptions: 1.m
Group R-J Occupancies, portable fire extinguishers shall be required only in locations
specified in Iterns 2 through 6 where each dwelling unit is provided with a portable
fire emi.`guisher having a minimum rating of1'A:10'B:[.2.m Group Eoccupancies,
portable fire extinguishers shall be required only in locations specified in items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum rating of 2-A:20-8:C.3. In storage areas of Group S occupancies where
forklift, powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.I Each vehicle shall be equipped with a10'
pound.40A:80BIe/uinQuisherafDxedroxhevehideusingamnundngbracket
approved by the extinguisher manufacturer,or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on-site to replace a discharged extinguisher. 3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.3.6. Inspections of vehicle-
Mounted extinguishersshaUbepedormeddai|y.2.VWrhin3Ofeet(g144mrn)dissanoe
of travel frorn commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.1n areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
structures under construction,except Group R-3 occupancies,in accordance with
Section 3316.1.5.vVhenerequired by the sections indicated in Table 9U6.1.6.Speda|'
hazardareas'inc|udingbutnot|imixedtolaboratories'conoputprroomsand
generator rooms,where required by the fire code official, Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or Structures where aportable fire extinguisher suitable xo the hazard of the location
io provided on the vehicle of visiting personnel.
Inspector:BARRYSTRATTON'Comments:Need[Odetecrorin vicinity ofthe
bedrooms.
Location: Bedrooms
FAIL 907.2.11 'Single-and Listed single-and nou|dp|e'station smoke alarms complying with UL217shall be
nnu|dple'stationsmnoke installed in accordance with Sections 007.J.11.1 through 9O7.2.11.7 and wFPA7J.
a|arms,
Inspector:BARRY STRATTON-Comments:Smoke detectors needed in each bedroomi,
outside bedroornx'and inbasemnnr.
Location: Not Provided
FAIL R6' Exterior Structure Is the exterior of the structure maintained in good repak,structurally sound and
sanitary state?(|PM[3O4)
Inspector:8ARRvSTRATTOm Comments:Basement foundation pushing wall inin
' bedroom in basement. Rotten windows need replaced.Cranks on windows missing
and some windows do not open.
Location: Not Provided
Pn"te^or.oo/`+oozs9,m.-�S
Page aor4
, . .
`STATUS ` COPE DESCRIPTION
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(|PM[305)
Inspector:8ARRYSTRATTUN Comments:Sink top not secured to cabinet.Tub
surround needs replaced. Register covers missing. Duct cleaning needed. No egress
window in basement that is being used asa bedroom. Kitchen flooring not
maintained. Front door blocked.Appearance of mold in kitchen cabinets. Hanging
wire in basement at base ofstairs.
Location: Bathroom and upstairs
FAIL R6.13. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of68F?(|phx[602.2)
Inspector:BARRvSTRxTToN Comments:Register covers missing and registers
covered soot
Location: Registers
FAIL m5.[. mechanica|Eqiupmenr Are mechanical a[D[Dliances properly installed and maintained in good working
condition?(|P/w[6OI1}
Inspector: BARRvSTRATTON Comments:Water heater installed in2017 did riot have
permits orinspections.
Location:Basement
FAIL R6.D. Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or receptacle with a GF[|. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have Gp[|
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector:BARRvSTR/gTON Comments:Outlet covers needed
Location: Basement
6ENEn4LmoTpS
BARRYSTR/Q7ON'UQ/14/2023@Ug:48 Tenant advised nothing has been done.Also stated unit is being sold.
`
mE/mspernmmoxrc _
09/11/2OZ3
~m°*""om`wzmy@ 09:43
Page 3or4
. -
CONTACT SIGNATURE
Ko Ohn
Signed on:08/14/2023 @ 09:48 L
INSPECTOR SIGNATURE
BARRY STRATTON
51)
Signed on:08/14/2023 @ 09:48
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
P,n:ect 1
Page 4 of 4