RENTAL INSPECTION - 1115JANNEY AVE- 8-15-23 FOR BILLING INQUIRY: (319)291-4323
LDescription I Total Price J
REINSPECTION FEE 1ST $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24177 08/28/2023 09/30/2023 2024-00000062 $50.00
Less Prepayment $0.00
Total Due — $50.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
t ec.,, 411. .2)
WATERLOO FIRE RESCUE 22�� 11111,
INSPECTION REPORT
T&S PROPERTIES MANAGE li LLC, 111 S JANNEY AVE,WATERLOO IA 01 `\
DETAILS
Inspection Date:08/15/2023 I Inspection Type: Rental Inspection i Inspection Number: 10653 I Shift: N/A ! Station: N/A 'l
Unit: N/A l Lead Inspector: BARRY STRATTON ( Other Inspectors: N/A I Fee:$50.00
A/4/X r F/3,
STATUS CODE DESCRIPTION
FAIL 1010.2 Door operations. Except as specifically permitted by this section,egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or
effort.
Inspector: BARRY STRATTON-Comments: Front door jamb
Location:Unit 3
FAIL 1204.10- Fire extinguisher. A listed portable fire extinguisher complying with Section 906 with a minimum rating
of 2-A:20-B:C shall be provided not more than 50 feet(15 240 mm)from the portable
generator.
Inspector: BARRY STRATTON-Comments: Need fire extinguishers in all units.
Location: Not Provided
FAIL 315.1 -General. Storage shall be in accordance with Sections 315.2 through 315.6. Outdoor pallet
storage shall be in accordance with Sections 315.2 and 315.7. Exception:Wood and
wood composite pallets stored outdoors at pallet manufacturing and recycling
facilities and complying with Section 2810.
Inspector: BARRY STRATTON-Comments:Remove all debris from area.
Location: Laundry Room
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector:BARRY STRATTON-Comments:Open electrical boxes and not cover on fan.
Supply lines to washing machine not not secured in space. Still not done
Location: Laundry Room
Page 1 of 3
. .
STATUS CODE _ mWSCw0PnION .
FAIL 703.1 Maintaining Materials and firesuop systems used no protect mennbnane and through penetrations
protection. in fire-resistance-rated construction and construction installed to resist the passage
of smoke shall be maintained.The materials and finastop systems shall be securely
attached to or bonded to the construction being penetrated with no openings visible
through or into the cavity of the construction.Where the system design number is
known,the system shall be inspected to the listing criteria and manufacturer's
installation instructions.
Inspector:8AKRYSTR/gTON Comments:Holes in walls
Location:Laundry Room
FAIL 907.2.1 1 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.1 1.1 through 907.2.11.7 and NFAA 72.
alarms.
Inspector: 8ARRv STRATTOm Comments:Smoke detector missing in unic 3 and
laundry room.
Location: Unit]
FAIL n4 Exterior Property Areas |s the exterior property area maintained in a dean,safe'and sanitary condition?This
includes grading and drainage'sidewalks and driveways'weeds' and pest
infestations.(|PK4[302)
Inspector:BARRY STRATTUN Comments:Deck railing is loose and need
replaced/repaired. Railing need to withstand the imposed loads required by code.
Still not done
Location: Deck
FAIL R5 ExceriorSu'ucture /s the exterior of the structure maintained ingood repair' struccuraUysound and
sanitary state?(|PrN[3O4)
Inspector: BARRY STRATTON [onnnents: Birds nesting in sofir at-ea. Still not
corrected
Location:Sofit
FAIL R5 Interior Sz/ucrure Has the interior ofthe structure and equipment inside been maintained in Sood
repair,structurally sound,and in a sanitary condition?(|PMC 305)
Inspector:BARRvSTR/QTUw Comments:Infestation needs excerminacion,carpets
need cleaned,door jamb needs repaired/replaced at lock set
Location:Unir#3
FAIL R6.C. Mechanical Eqiupmenr Are mechanical appliances properly installed and maintained in good working
condition?(1PyNC 60I1)
Primed=03',5/eoo�,�so
Page zor3
STATUS CODE DESCRIPTION
Inspector: BARRY STRATTON-Comments: Bath tub in unit leaking into lower unit
Location: Unit 3
REINSPECTION DATE
09/12/2023
CONTACT SIGNATURE
T&S Properties LLC 6/V\PO L\pi\p,
Signed on:08/15/2023 @ 12:50
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:08/15/2023 @ 12:50