Loading...
HomeMy WebLinkAbout1821 E RIDGEWAY AVE OF W q TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4� 08/28/2023 09/30/2023 2024-00000063 $250.00 v / O • 0 Customer#: 24178 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 1821 E RIDGEWAY AVE 715 Mulberry St 5001 1ST ST SUITE 105 #221 WATERLOO, IA 50703 ATTN: BARDOT DUBILO CEDAR RAPIDS, IA 52402 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1821 E RIDGEWAY AVE- 8-15-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24178 08/28/2023 09/30/2023 2024-00000063 $250.00 Less Prepayment $0.00 Total Due $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 0)36,1.14 1 ottz, n WATERLOO FIRE RESCUE INSPECTION REPORT QO\ 1821 E RIDGEWAY AVE SINGLE FAMILY RENTAL,1121 E RIDGEWAY AVE, WATERLOO IA 5 7Q 7i` DETAILS SVP-. N N ' aav Da\-300 Inspection Date:08/15/2023 1 Inspection Type:Rental Inspection 1 Inspection Number: 10629 1 Shift: N/A Station: N/A 1 Unit: N/A 1 Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 STATUS CODE DESCRIPTION FAIL 1010.2- Door operations. Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector:BARRY STRATTON-Comments:Back door has a latch lock that needs removed. Latch is still on door Location:Not Provided FAIL 1031.1 -General. Emergency escape and rescue openings shall comply with the requirements of this section. Inspector: BARRY STRATTON-Comments:Egress window installed in basement did not get inspection to ensure installation meets code. Location: Not Provided FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector: BARRY STRATTON-Comments: Unsafe electrical in house and garage. Open terminations in basement and garage,open terminations in greenfield, switches and outlet boxes hanging by wires,grounding in gone since pex is used for water lines.Open wires in garage,wires hanging by rafters.All wiring done needs removed.Wiring not done by a licensed contractor and no permits were obtained. Missing outlet/switch covers throughout house and garage. Location: Not Provided FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.7 and NEPA 72. alarms. Inspector:BARRY STRATTON-Comments:None Location: Not Provided -zed on 08/1 512023 1:1O:47 Page 1 of 4 STATUS CODE DESCRIPTION FAIL R 1 - Unsafe Structures Is the structure found to be dangerous to the life, health, property or safety of either the public or occupants of the structure?(IPMC 108.1.1) Inspector: BARRY STRATTON-Comments:Electric, plumbing,construction work Location: Not Provided FAIL R2 -Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator, moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector:BARRY STRATTON-Comments:Electric, plumbing,wall/floor construction. No treated plates. Location: Not Provided FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Electric, plumbing, and construction work being done without permits and inspections. Peeling paint and basement stairs need repaired/removed. Location: Not Provided FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments: Electric work, plumbing work,and construction in basement.Basement stairs Location: Not Provided GENERAL NOTES BARRY STRATTON-08/15/2023 @ 10:43 9-3-8:PENALTY;ABATEMENT OF VIOLATIONS:A.Any person violating any provision of this chapter shall be deemed guilty of a municipal infraction and,upon conviction thereof,shall be punished accordingly. B. If any electrical work,including construction or repair, is performed within the city contrary to the provisions of this chapter,it shall be deemed a municipal infraction and,in addition to penalties described,shall be abated in accordance with this chapter. C.The doing of any act prohibited or declared to be unlawful,an offense or a municipal infraction by this chapter or the national electrical code,or the omission or failure to perform any act or duty required by this chapter or the national electrical code, is,unless another penalty is specified, punishable as provided in section 1-3-2 of this code.(Ord.5392,3-20-2017) Printed on 08/1512023 rd 10.47 Page 2 of 4 GENERAL NOTES BARRY STRATTON-08/15/2023 @ 10:43 80.28 Licensing,is added as follows:(a)License Required.Electrical work being done with out a permit. Need a licensed contractor. BARRY STRATTON-08/15/2023 @ 10:44 IRC R105: Failure to obtain permits for construction in basement.Work being done without permits and inspections.Citations shall be issued for failure to get licensed contractors. BARRY STRATTON-08/15/2023 @ 10:43 9-1A-1:SCOPE OF LICENSES:A.Residential Building Contractor: 1.License Required: Under the city building code,all residential building contractors who contract with an owner to construct or improve dwellings for habitation by one to four(4)families and who provides two(2)or more special skills(services)for a consumer, must be licensed unless exempt under the provisions noted in subsection 9-1A-2F of this article. Not licensed to do work in the City of Waterloo BARRY STRATTON-08/15/2023 @ 10:45 9-4-6:WORK REQUIRING PERMIT OR APPROVAL: No building or premises shall tap any water or sewer main or have installed any private building sewer,water service, private sewage disposal plant or private water system or have connections,extensions, replacements, removals or additions of any nature to the sanitary plumbing or water supply system or disconnection of any fixture or change in the plumbing system before notifying the plumbing inspector or his assistant and securing a permit or authority to proceed with the work.(Ord.5392,3-20-2017;arnd.Ord.5673, 11-21-2022) No permits of inspection for plumbing work in basement and upstairs bathroom. BARRY STRATTON-08/15/2023 @ 10:45 Violations exist with Electric Code, Plumbing Code,Residential Code,&Rental Code. BARRY STRATTON-08/15/2023 @ 10:45 All work being done or that has been done will need to be done by licensed contractors for each field.All work done will need to be removed and re-done.Corrections still have not been done. BARRY STRATTON-08/15/2023 @ 10:46 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official.Any person who shall occupy a placarded premises or shall operate placarded equipment,and any owner or owner's authorized agent who shall let anyone occupy a placarded premises or operate placarded equipment shall be liable for the penalties provided by this code. No occupancy until work is permitted and inspected.Citations shall be issued. REINSPECTION DATE 09/12/2023 Printed on 08,15/2023 10:47 Page 3 of 4 CONTACT SIGNATURE Joyce Wood 6 Mk Signed on:08/15/2023 @ 10:46 INSPECTOR SIGNATURE BARRY STRATTON Signed on:08/15/2023 @ 10:46 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratten@waterloo-ia.org (319)231-9147 Panted on 08/15/2023(c 10:47 Page 4 of 4