Loading...
HomeMy WebLinkAbout212 IRVING ST OF W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE „ ' 08/10/2023 09/15/2023 2024-00000047 $250.00 • •111 r01 '11-11 II• • ,. y_= v 0 s 7d1�'� Customer#: 24033 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IA INVESTMENT PROPERTY 715 Mulberry St 5001 1ST AVE SE SUITE 105,221 WATERLOO, IA 50703 CEDAR RAPIDS, IA 52402 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 212 IRVING ST- 7-27-23 FOR BILLING INQUIRY: (319)291-4323 L Description ( Total Price J REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24033 08/10/2023 09/15/2023 2024-00000047 $250.00 Less Prepayment $0.00 Total Due $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO ������� �� ����� 0��������� Nr���0� ��m�w�����m� ° INSPECTION REPORT /A INVESTMENT PROPERTIES0LC,212/RyING ST, WATERLOOJA S0703 ocno/LS Inspection Date:U7/27/2U23 \ Inspection Type: Rental inspection \ Inspection Number: 1O577 \ Shift: N/A \ Station: N/A \ Unit: N/A Lead Inspector:8ARRY5TRATT0N Other Inspectors: N/A \ Fee:$25O.0D mTmIMS CODE DESCR.IPTION ` FAIL 1010'1'g Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector: BARRYSTR/QTON Comments:Front door needs replaced.Security hardware damaged and does not work. Location: Not Provided FAIL 1031'7 Emergency escape Required emergency escape and rescue openings shall be maintained in accordance with d in and the andrescueopenin�� vvt eco e ' . ernergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of key'tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. � Inspector:8ARRvSTRATTUN Comments:Windows broken Location: Not Provided � � FAIL 6051 Abatement of |denz�ede|eoroa| hazards shaUbe abated. |dentU�edhazardous e|ec��a|condhions electrical inpermanentwiringshaUbebroughtcothpauendonofthenasponsib|ecodeofficiai — Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not beused. Inspector: BARRvSTRATTON Comments:Outlets covers missing,outlets pulling out of walls Location: Not Provided F-=-d onmo7j�i� a�� - ' STATUS CODE DESCRIPTION FAIL 906'1 -Where required Po�abha fire extinguishers shall be installed in all of the following locations: 1. |nnew and existing Group A,B'�F, H' \.M'R'1' R-2, R-4 and 5 occupancies.Exception:|n Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1`A:1U'B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. in areas where flammable or combustible liquids are stored, used or dispensed.4.()n each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator MOMS, where required by the fire code official. Inspector:BARRvSTRATT0m'Comments:None Location: Not Provided FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be nnu|tip|e'statinnsmnke installed in accordance with Sections 907.2.11.1 through 0O7.2.11.6and NFPA7Z. alarms � Inspector: BARRYSTR/QTON Comments:Smoke detectors needed in each bedroonrl and in basement also outside ofbedrooms. Location: Not Provided FAIL R1 Unsafe Structures is the structure found ro be dangerous rothe life,health, property or safety ofeither the public or Occupants of the structure?(|PK4[ 1O8.1.1) Inspector: 8ARRYSTR/TT0N [omments:Floors and stair handrail,electric system Location: Not Provided FAIL R3 Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IP,,K Occupancy 108.1.3) Inspector:8ARRY5TRATTON Comments:Mold and structural issues wichfloors Location:Not Provided FAIL R5 Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(|PK4[3U4) Inspector: BARRvSTR/ATON [ommencs: Roof leaks,f/onr porch and stairs need replaced. Location: Not Provided FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good repair'structurally sound,and in a sanitary condition?(|PM[306) Printed""o,/.1nzvza�ov.^` Page 2of 4 . . ' STATUS CODE ' ` Inspector:BARRvSTR/QTON Comments: Roof Leak,ceilings in bedrooms and dining room damaged from water leak,floors damaged and need replaced throughout house,toilet needs re-set on floor on 1 st floor and 2nd floor-toilet does not work, bath tub on 1 st has leak that runs on floor,and sink leaks. Kitchen sink does not drain, peeling paint throughout house,door hardware missing on doors,broken windows need repaired. Handrail and balusters need replaced going upstairs.Mice infestation. Location:Not Provided FAIL n&A. Interior Structure- Were any unsafe conditions noted during the interior inspeoion?(|PM[3O5.1.1) Unsafe Conditions Inspector: 8ARRvSTRATT0N Comments:Floors unstable, porch floor and stairs unstable Location: Not Provided FAIL R8.8. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature ofO8F?(|PK4[bO3.2} |nspectocBARRY5TRATTUN Comments:Register covers missing and some not attached,gravity ducts not working and full ofdebris. Location: Not Provided GENERAL NOTES � 8ARRYSTRA7TUN 87/27/2823@00:40 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official.Any person who shall occupy a placarded premises or shall operate placarded equipment,and any owner or owner's authorized agent who shall let anyone occupy a placarded premises or operate placarded equipment shall be liable for the penalties provided by this code. B«nRvSTR/TT0N 07/27/2023@09:41 111.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe,unlawful or,because of the degree to which the structure is in disrepair or lacks maintenance,is insanitary, vermin or rat infested'contains filth and contamination,or lacks ventilation, illumination'sanitary or heating facilities or other essential equipment required by this code,or because the location of the structure constitutes a hazard to the Occupants of the structure or-to the public. R8NNSPECT0ON DATE 88/3O/2O23 p^"°uo"or/z,,zoza Ca-vo^, Page oor* CONTACT SIGNATURE Joyce Wood IL-7\1AL Signed on:07/27/2023 @ 09:41 INSPECTOR SIGNATURE BARRY STRATTON Signed on:07/27/2023 @ 09:41 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 07/27/2023 t:*09:41 Page 4 of 4