Loading...
HomeMy WebLinkAbout420 LANE ST OF W.4 TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 09/05/2023 10/10/2023 2024-00000069 $250.00 7vill Customer#: 23960 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MARILU SANCHEZ 715 Mulberry St 827 E 7TH ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 420 LANE ST- 8-30-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price J REINSPECTION FEE 3RD $250.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23960 09/05/2023 10/10/2023 2024-00000069 $250.00 Less Prepayment $0.00 Total Due $250.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. . . . ^ WATERLOO 0��0��� RESCUE \ , [� 0���������N����� Nr���N� INSPECTION REPORT vr� , _ _��E � MARILU SANCHEZ SINGLE FAMILY RENTAL, 420 LANE ST, WATERLOO 1A 50703 DETAILS ` Inspection Date:07/27/2023 \ Inspection Type: Rental inspection \ Inspection Number: 18576 \ Shift: N/A ( Station: N/A � Unit: N/A \ Lead Inspector:BARRY STRATTDN \ Other Inspectors: N/A | Fee:$250.00 441y��� yrAruS CODE DESCRIPTION FAIL 1O1O 1 g Door operations Except as specifically permitted by this section,egress doors shall be readily ' � idwithoutthe use of key or special knowledge or ''' - openab\e from the egress side effort. Inspector: BAKRY STRATTON Comments:None Location: Not Provided FAIL 1031.7 Emergency escape Required emergency escape and rescue openings shall be maintained in accordance ' with the code in effect at the time of construction,and the following:Required and rescue openings w e ' ~ er �-�ency escape and rescue openings shall be operational from the inside nfthe room it uxthe use of keys or tools. Bars'grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net dear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector:8ARRv STRxTTUN Comments:Windows do not work and some are broken Location: Not Provided �A|L 605.1 Abatement of identified electrical hazards shall be abated. Identified hazardous electrical conditions ' i frh ''- electrical hazards in permanent wiring shall be brought to the attention o e responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON Comments:Open electrical boxes in living room and by back basement stairs. Exposed electrical wires in unit. Need globes on all light. Remove all extension cords.Burnt electrical outlets need replaced by licensed electrician. Need approved covers on all outlets and switches. Lighting requirements for the upstairs not being met. Nothing has been done Location:Not Provided ` Pnnted"" �1o*z Page 1urm . . STATUS CODE mesCoo^r/om FAIL 703.2 Upeningproteoives Opening protectives,shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance nf opening protecdves shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BARRYSTRATTON Comments:None Location: Not Provided FAIL 906.1 Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B' E, F, *' |' /N' R'1. R'2'R'4 and 5 occupancies. Exception: In Group R'2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 3through b where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 1 O-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.l |n areas where flammable orcombustible liquids are stored, used or dispensed.4.On each floor of structures under construction,except Group R'3 occupancies, in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator roorns, where required by the fire code official. Inspector: QARRY5TRATTON Comments:None Location: Not Provided FAIL 007.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL217 shall be multi p|e'station smoke installed in accordance with Sections 007.2.11.1 through yO7.2.11.6and NFPA72. alarms Inspector:BARRYSTRATTON Comments:Need smoke detectors installed tomeet rental requirements. Location: Not Provided FAIL 015.1 General Cat-bon monoxide detection shall be installed in new buildings in accordance with Sect}onsy15.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRvSTRATTOw Comments:CO detectors need installed in vicinity of the bedrooms nn main level and upstairs. Location: Not Provided Printed=o-/z-zo�- -1o�.z� Page zor8 ` . STATUS CODE DESCRIPTION _ FAIL R2 Unsafe Equipment Was the presence Of Unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment, elevator,moving stairways,electrical wiring,and flammable liquid containers.(|PyW[ 108.1.2) Inspector: BARRYSTRATTON Comments:Furnace and water heater Location: Not Provided FAIL R3 Unfit for Human Is the structure found to be fit for hurnan occupancy according to the code?(1P11'.,1C Occupancy 108.1.3) Inspector: BARRvSTRATTUN Comments:Condition of unit does not meetcode requirements. Potential lead base paint inhouse. Location: Not Provided FAIL R4 Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(|PrNC302) Inspector:BARRYSTRATTON Comments:Roof and sofit area have large holes that need corrected. Need landing replaced at front of residence. Need rear entrance landing and stairs replaced. Need handrails on exterior stairs. Broken window and windows that do not open.Exterior doors need replaced. Gutters missing need replaced. Need screen on all windows. Location: Not Provided FAIL R5 Exterior Structure Is the exterior of the structure maintained in good repair'struccura|\y sound and sanitary state?(|PrW[3O4) Inspector: BARRYSTRATT0N Comments:Doors,windows,stairs,landings,paint, holes in walls,foundation cracks. Location: Not Provided FAIL R6 ,nceriorSo'ucture Has the interior of the structure and equipment inside been maintained ill good repair,structurally sound,and in a sanitary condition?(|PrNC3O5) p,m°m""m02,/o02»Cm 09.20 mvAroS CODE DESCRIPTION Inspector:BARRYSTRATTON Comments:Doors,windows, holes in walls,peeling paint,collapse ceilings by back door,flooring in unit needs replaced in several areas, carpet not tacked down,bath cabinet needs replaced, porch and landing at cloor unsafe, hardware nn doors missing,open ducts in basement not attached zo registers,handrail oc basement missing,balusters missing toupstairs,guard railing to upstairs unstable/unsafe,base boards and trim m issi ng/da ill aged, back doors need replaced. Bathroom on 2nd floor is not functional. Flooring throughout needs replaced. Location: Not Provided FAIL R6.A. Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRvSTRATTUN Comments:Mold,fire safety requirements not being met Location: Not Provided FAIL RS.B. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature ot68F7(|PrN[6U2.2) Inspector: BARRYSTRATTON Comments:No permits on furnace installed. Citations shall be issued for failure correct issues.Chimney liner failed inspection and need corrected. Location: Not Provided FAIL R6.[. rWechanica| Eqiupmenz Are mechanical appliances properly installed and maintained in good working condition?(|PM[6U3.1) Inspector: 8ARRvSTRAJTON Comments:Nn permits or inspection for new water heater installed. Missing discharge tube oil water heater.Citations shall be issued for failure tocorrect. Location: Not Provided FAIL R5.D. Receptacles Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle ora receptacle with a GFC|.Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle shall have GF[| protection,All receptacles shall have the appropriate faceplate cover.(IFIMC 6,065.2) Inspector: 8ARRYSTRATTON Comments:None Location: Not Provided GENERAL NOTES r-'"."*"""7/zr'mza�_Zov-10 Page 4 of 8ARRY5TRATTON 87/ 7/20Z3@O916 304.5 Foundation walls. Foundation walls shall be maintained plurnb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. 8ARRYSTKATTUN 07/37/2023@89:16 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains,gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. 8ARRYSTRAlTON 07/27/2023@09:16 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck,porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound' ingoodrepair.withp/operanchorageandcapab|eofsuppouinQthninnposed loads BARRv6TRATT0N 07/27/2023@p0916 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. 8ARRYSTRmTT0N 07/27/2023@89:16 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall be kept in sound condition,good repair and weather tight. BAnRYSTRATTON 07/27Q023@09:16 304.13.2 Openable windows. Every window,other than a fixed window,shall be easily npenab|e and capable of being held in position by window hardware. 8ARRYSTRAlTON 87/27/2023@09:15 304.14 Insect screens. During the period from[DATE]to[DATE],every door,window and other outside opening required for ventilation of habitable rooms,food preparation areas,food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured,packaged or stored shall be supplied with approved tightly fitting screens of minimurn 16 mesh per inch(116 mesh per 25 mm),and every screen door used for insect control shall have a self-closing device in good working condition BARRYSTRA7T0N 07/27/I023 @Og:16 305.1 General.The interior of a structure and equipment therein shall be maintained in good repair,structurally sound and in a sanitary condition. Occupants shall keep that part of the structure that they occupy or control in a clean and sanitary condition. Every owner of a structure containing a rooming house, housekeeping units,a hotel, a dormitory,two or more dwelling units or two or more nonresidential occupancies, shall maintain, in a clean and sanitary condition,the shared or public areas of the structure and exterior property. Printed""m,2nonzaCcomzn Page oma ` 6EmERALmOTES 8AnRY5TRAJTUw 07/27/ 023@O918 305.3 Interior surfaces. interior surfaces,including windo�s and doors,shall be ma\nrainedin good,clean and sanitary condition. Peeling, chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall becorrected. BARRYSTnATT0N 07/27/2023@)00:17 305.4 Stairs and walking surfaces. Every stair,ramp,landing,balcony, porch,deck or other walking surface shall be maintained in sound condition and good repair. BARnvSTnAl7ON 07/37/2023@09:17 305.6 Interior doors. Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs,headers or tracks as intended by the manufacturer of the attachment hardware. BARRvSTRAlTOm 07/27/2023@P09:17 300.1 Infestation.Structures shall be kept free from insect and rodent infestation. Structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health.After pest elimination, proper precautions shall betaken to prevent reinfestation. 8ARRYSTRATTUN 0727/2023@)80:17 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1,except that a window shall not be required in such spaces equipped with a mechanical ventilation system.Air exhausted by mechanical ventilation system from a bathroom or toilet room shall discharge to the outdoors and shall not be recirculated.Current fan is not rated for a wet location. BARRYSTRA7TON 07/27/2023@P00:18 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with the ventilation requirements for habitable spaces as required by Section 403.1, except that a window shall not be required in such spaces equipped with a mechanical ventilation system.Air exhausted by a mechanical ventilation system from a bathroom or toilet room shall discharge tothe outdoors and shall not be recirculated. No permits or inspections for new water heater. BARRY5TRA7T0N 07/37/2023@09:18 603.1 Mechanical equipment and appliances. Mechanical equipment,appliances, fireplaces,solid fuel-burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition,and shall be capable ofperforming the intended function.Chimney liner failed inspection. BAnnYsTnArTom 07/27/2023@09:18 604.3 Electrical system hazards.Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service,improper fusing, insufficient receptacle and lighting outlets, improper wiring or installation,deterioration or damage,or for similar reasons,the code official shall require the defects tobp corrected to eliminate the hazard. px"t eo""mo7/2oarov.�o Page nora ` . ' GfVExtAL NOTES ' ' 8ARKvSTRATTON 07/27/2023@0918 605.1 Installation. Electrical equipment,wiring and appliances shall be properly installed and maintained ina safe and approved manner. BARRYSTRATTON 07/27/2023@80:18 605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two separate and remote receptacle nutlets. EveryiaundryareashaUcontainnot|essthan one grounding-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. BAnRv5TRxTTON 07/27/2023@,00:18 605.3 Luminaires. Every public hall,interior stairway,toilet room,kitchen, bathroom, laundry room,boiler room and furnace room shall contain not less than one electric |uminaire. Pool and spa luminaires over, 15 VshaU have ground fault circuit interrupter protection. 8ARRYSTRAlT0N 07/27{2023@)09:18 111.8 Prohibited occupancy.Any occupied structure condemned and placarded by the code official shall be vacated as ordered by the code official.Any pet-son who shall occupy a placarded premises or shall operate placarded equipment,and any owner or owner's authorized agent who shall let anyone occupy a placarded prernises or operate placarded equipment shall be liable for the penalties provided by this code. Unit is occupied by new tenant. Unit has not passed inspection to be occupied. 8ARRY STRAlTON 07/27/2023 @ 09:18 111.6 Transfer of ownership. it shall be unlawful for the owner of any dwelling unit or structure who has received a compliance order or upon whom a notice of violation has been served to sell,transfer, mortgage,lease or otherwise dispose of such dwelling unit or structure to another until the provisions of the compliance order or notice of violation have been complied with,or until such owner or the owner's authorized agent shall first furnish the grantee,transferee,mortgagee or lessee a true copy of any compliance order or notice of violation issued by the code official and shall furnish to the code official a signed and notarized statement from the grantee,transferee, mortgagee or lessee,acknowledging the receipt of such compliance order or notice of violation and fully accepting the responsibility without condition for making the corrections or repairs required by such compliance order or notice of violation, 8ARRYSTRAlTON 07/27/2023@09:10 PBX conversation with daughter and additional time was granted to get corrections done.As of this date no permits or inspections have been obtained.Several weeks additional time was given to gain compliance.Still no progress to bring property UID tO the rental code mrmxSPf Cm,mmDmM o8/38/2023 v,m.eu""vr,nzocaL&oo.zv Page 7or8 CONTACT SIGNATURE Marilu Sanchez Signed on:07/27/2023 @ 09:19 INSPECTOR SIGNATURE BARRY STRATTON Signed on:07/27/2023 @ 09:19 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 07/27/2023 CC?09 20 Page 80f8