HomeMy WebLinkAbout523 REED ST O F W A TF INVOICE DATE DUE DATE INVOICE# TOTAL DUE
�0 07/26/2023 08/30/2023 2024-00000045 $250.00
f
o
a.
iiiis9
Customer#: 24156 Please Make Check Payable and Remit To:
City of Waterloo
A TTN: City Clerk/Accounts Receivable
O'NEAL PROPERTIES LLC 715 Mulberry St
637 DAWSON ST WATERLOO, IA 50703
WATERLOO, IA 50703
Amount Enclosed.
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION- 523 REED ST- 7-25-23 FOR BILLING INQUIRY: (319)291-4323
[Description Total Price J
REINSPECTION FEE 3RD $250.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES _
24156 07/26/2023 08/30/2023 2024-00000045 $250.00_
Less Prepayment $0.00
Total Due—* $250.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
_ 1/\
WATERLOO FIRE RESCUE Q .
INSPECTION REPORT
S23 REED ST LITCHFIELD ADDITION LOT 18 BLK 4, 523 REED ST, WATERLOO IA 50703 V --)
eb
DETAILS
Inspection Date:07/25/2023 I Inspection Type: Rental Inspection I Inspection Number: 10296 5 ift: N/A ! Station: N/A
Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$250.00 QJ
STATUS CODE DESCRIPTION
FAIL 1031.1 -General. Emergency escape and rescue openings shall comply with the requirements of this
section.
Inspector:BARRY STRATTON-Comments: Replace/repair all broken windows.
Location: Not Provided
FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions
conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official.
hazards. Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes Conditions that constitute an electrical shock or fire hazard
shall be abated not be used.
Inspector: BARRY STRATTON-Comments:Missing outlet covers, need 3'clearance to
electric panel,Open box with exposed wires in stairway to upstairs, Light fixtures
hanging from ceiling,and all lights need globes.SEU Cable on exterior of house needs
replaced.SEU Cable is not strapped to meet code requirements.
Location: Not Provided
Pinted on 07i2512023,e 08:37
Page 1 of 5
STATUS cmom oeSCRopr/wN
'
906.1 Where required. Portable fire extinguishers shall be installed in all of the following locations: 1]nnew
and existing Group A, Q' � F, H'1, N\R,1'R-2' R`4 and S occupancies. Excepdons: 1.m
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.In Group E Occupancies,
portable fire extinguishers shall be required only in locations specified in Items 2
through 6 where each classroom is provided with a portable fire extinguisher having
a minimum raring ofZ`A:28'8:[.3. In storage areas of Group S occupancies where
forklift,powered industrial truck or powered cart operators are the primary
occupants,fixed extinguishers,as specified in NFPA 10,shall not be required where in
accordance with all of the following:3.1.Use of vehicle-mounted extinguishers shall
be approved by the fire code official.3.2. Each vehicle shall be equipped with a 10'
pound.4OA:8O8:[extinguisheraffixedtorhevehideusingamounxingbrackez
approved by the extinguisher manufacturer or the fire code official for vehicular use.
3.3. Not less than two spare extinguishers of equal or greater rating shall be available
on-site co replace a discharged extinguisher.3.4.Vehicle operators shall be trained in
the proper operation,use and inspection of extinguishers.I5. Inspections o[vehicle-
mounted extinguishersshaUbeperformnddai|y.Z.Vvithin3Ufeet(O144mm)distance
of travel from commercial cooking equipment and from domestic cooking equipment
in Group 1-1; 1-2,Condition 1;and R-2 college dormitory occupancies.3.In areas where
flammable or combustible liquids are stored, used or dispensed.4.On each floor of
structures under construction,except Group R-3 occupancies, in accordance with
Section 3316.1.S.VVhene required by the sections indicated in Table yU6.1.6.Specia|'
hazardareas' including but not limited to laboratories,computer rooms and
generator rooms'where required by the fire ozdp official. Exception: Portable fire
extinguishers are not required at normally unmanned Group U occupancy buildings
or structures where a pot-table fire extinguisher suitable to the hazard of the location
is provided on the vehicle of visiting personnel.
Inspector: BARRvSTRATTON Comments:Need Fire Extinguisher in unit.
Location: Not Provided
FAIIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multi p|e'srarion smoke installed in accordance with Sections 9U7.Z.11.1 through 907.Z.11.7and NFPA7J.
alarms.
Inspector:8ARRYSTR/QTUN Comments:Need detectors in each bedroom, outside
bedrooms'and in basement
Location: Not Provided
FAIL 015.1 General. Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 015.6.Cat-bon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRvSTR/QTOm Comments:Need CO detectors installed in vicinity of
any bedroom.
Location: Not Provided
p,mtev""mo,ov�Cc,03.37
Page z«ro
onuruo CODE DesCm/prxON'�
^ `
'
F.A|L R3 Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPIVIC
Occupancy 108.1.3)
Inspector: 8ARRvSTRATTON Comments:House in cut-rent condition is not habitable.
Location: Not Provided
FAIL R4 Exterior Prope/cyAreas is the exterior property area maintained in a clean, safe, and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,arid pest
infestations.(|PM[3CQ)
Inspector: BARRYSTRATTON Comments:Debris all around rear ofproperty.
Location: Not Provided
FAIL R5 Exterior Structure |s the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(|PMC3U4)
Inspector:BARRvSTRATTON Comments:Foundation, Roof and gutters
Location: Not Provided
FAIL R6 Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and ina sanitary condition?(|PK8[305)
Inspector: 8ARRvSTR/TTON Comments:Peeling paint, holes in walls flooring inliving
room and kitchen needs replaced,living room ceiling collapse,Walls in bathroom,
register vent covers, kitchen counters and cabinets need replaced, basement stairs
need replaced, upstairs floors warped, missing handrails to basement and upstairs,
tub surround needs replaced, Foundation needs repaired,rnice and cockroaches
need exterminated.
Location: Not Provided
FAIL R6.D. Receptacles Every habitable space in a dwelling shall contain not less than two separate and
remote receptacle outlets. Every laundry area shall contain not less than one
grounding-type receptacle or receptacle with a GF[|. Every bathroom shall contain
not less than one receptacle.Any new bathroom receptacle shall have GFC|
protection.All receptacles shall have the appropriate faceplate cover.(IPMC 605.2)
Inspector:BARRYSTRATTUN Comments:Need approved outlets covers onswitches
and outlets,
Location: Not Provided
GENERAL NOTES
Printed on N!`_02nig�mor
Page 3uro
_
. . ^
B«RRvSTRATTON 07/35/2023@08:36 9-7-4 9-7-5: Need all rental units registered with the City of Waterloo Still not registered
2023
yAoRYSTRATTON 07/25/2023@p08:36 SO4.1Gpnera|.Plumbing fixtures shall be properly installed and maintained inworking
or-der,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condixion. Kitchen sink
does not work.Tub Surround needs replaced.
8ARRYSTRATTON 87/25/2023@08:36 5O5.3 Supply.The water supply system shall be installed and maintained to provide a
supply of water xnplumbing fixtures,devices and appurtenances in sufficient volume
and at pressures adequate to enable the fixtures to function properly,safely,and free
from defects and leaks.
BARRvSTRATTUN 07/25/2023@08:36 605.1 Installation. Electrical equipment,wiring and appliances shall be properly
installed and maintained in a safe and approved manner.605.2 Receptacles, Every
habitable space in a dwelling shall contain not less than two separate and remote
receptacle outlets. Every laundry area shall contain not less than one grounding-type
receptacle or receptacle with a ground fault circuit intenupter. Every bathroom shall
contain not less than one receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle outlets shall have the
appropriate faceplate cover for the location.
B^RnvSTRxTT0N 07/25/2023@08:36 305.1 General.The interior of a structure and equipment therein shall be maintained in
good repair,structurally sound and in sanitary condition. Occupants shall keep that
part of the structure that they occupy or control in a clean and sanitary condition.
Every owner of a Structure containing a rooming house,housekeeping units,a hotel,a
dormitory,two or more dwelling units or two or more nonresidential occupancies,
shall maintain, in a clean and sanitary condition,the shared or public areas of the
structure and exterior property.
BARRvSTRAlTON 07/25/2023@08:36 conditions shall be corrected.305.4 Stairs and walking surfaces. Every stair, ramp,
landing, balcony,porch,deck or other walking surface shall be maintained in sound
condition and good repair.
8ARRvSTRATTON 07/25Q023@a08:36 Correctionsnutdoneandunitisnowoccupiedbyadifferenttenant. Fai!uretobringto
code the City Shall issue citations for rental violations. Yoshita Thomas 319-504-8711
has been advised.
R8INSPECTION DATE
O8/22/2Q23
p,m,°v=n,/z�zuzaZno,s,
Page*uro
CONTACT SIGNATURE
Daejaun O'Neal
Signed on:07/25/2023 @ 08:37
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:07/25/2023 @ 08:37
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed on 07/25/2923 @ 03:37
Page 5 of 5