HomeMy WebLinkAbout325 COMMERCIAL ST 325 , ,,..,-- Ckl, WATERLOO FIRE RESCUE �PSERtoo INSPECTION REPORT I V Do SINGLE SPEED BREWING,325 COMMERCIAL ST,BLDG 325 COMMERCIAL ST,WATERLOO IA4,4,0026 S0702 DETAILS Inspection Date: 11/13/2023 Inspection Type:Annual Inspection(1Yr) 1 Inspection Number:9470 Shift: N/A i Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL i Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a __� - means of egress. y, r' -� Inspector:JEFF SIEBEL-Comments:remove obstructions to exit door.44"Pathway �' ;y must be maintained at all times.Unstable storage(stacked)not allowed next to exit : ., „ path. I.;k Location:employee entrance FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:remove obstructions(ladders)from exit path. Location: Next exit door west of employee exit. FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments: East Door out of the coffee shop. Location:repair egress lights Printed on 11/15/2023 @ 09:50 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments: Repair exit/egress light Location:South exit past end of bar FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector:JEFF SIEBEL-Comments: Repair blue light on wall.Cover dislodged and storage against fixture. Maintain proper clearances. Location: back hall FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions to electric panel. Maintain a minimum of 36"clearance at all times. Location:back hall with blue light. Printed on 11/15/2023 @ 09:50 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions to electric panel. Maintain a minimum of 36"clearance. Location: By Air compressor FAIL 603.9.4-Prohibited areas. Portable,electric space heaters shall not be operated within 3 feet(914 mm)of any combustible materials. Portable,electric space heaters shall be operated only in locations for which they are listed. Inspector:JEFF SIEBEL-Comments:remove electric heater from office. Location:Coffee Shop Office FAIL 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Inspector:JEFF SIEBEL-Comments:provide current hood cleaning inspection report with all discrepancies corrected.Currently 134 days past due.Contractor must upload report online to the compliance engine. Location: Not Provided GENERAL NOTES JEFF SIEBEL-11/15/2023 @ 09:23 annual inspection$80 REINSPECTION DATE 12/04/2023 Printed on 11/15/2023 @ 09:50 Page 3 of 4 CONTACT SIGNATURE Kegan Signed on:11/15/2023 @ 09:23 �� L INSPECTOR SIGNATURE JEFF SIEBEL Signed on:11/15/2023 @ 09:23 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11/15/2023 @ 09:50 Page 4 of 4