COMMERCIAL INSPECTION - 1955 HEATH ST- 10-17-23 FOR BILLING INQUIRY: (319)291-4323
L Description Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24260 11/16/2023 11/20/2023 2024-00000198 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE ZU0 ER&
INSPECTION REPORT411K)
UNITYPOINT ALUMNI HALL l CEDAR VALLEY IODS HILD '1955 HEATH ST BLDG 1955
HEATH ST,WATERLOO/A 50)03 Y
DETAILS DD o°
Inspection Date: 10/17/2023 ; Inspection Type:Annual Inspection(1Yr) 1 Inspection Numse+' 74 1 Shift: N/A 1
Unit: N/A Lead Inspector:JEREMIAH VANDYKE 1 Other Inspectors: N/A 1 Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 506.2-Key box maintenance. The operator of the building shall immediately notify the fire code official and provide
the new key where a lock is changed or rekeyed.The key to such lock shall be secured
in the key box.
Inspector:JEREMIAH VANDYKE-Comments:Master key needed for knox box,will
install on re inspect.
Location: Not Provided
FAIL 509.2-Equipment access. Approved access shall be provided and maintained for all fire protection system
equipment to permit immediate safe operation and maintenance of such equipment.
Storage,trash and other materials or objects shall not be placed or kept in such a
manner that would prevent such equipment from being readily accessible.
Inspector:JEREMIAH VANDYKE-Comments:Storage needs to be cleared around
furnace and sprinkler riser by 36 inches. Discussed on site on what we needed.
Location:Sprinkler riser room.
FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers
conditionsOpen electrical shall be provided for all switch and electrical outlet boxes.
terminations.
Inspector:JEREMIAH VANDYKE-Comments:Open Junction electrical box needs
covered.
Location:Sprinkler riser room
FAIL 606.3.3.2-Grease If during the inspection it is found that hoods,grease-removal devices,fans,ducts or
accumulation. other appurtenances have an accumulation of grease,such components shall be
cleaned in accordance with ANSI/IKECA C10.
Printed on 10/19/2023 @ 08:51
Page 1 of 3
STATUS CODE DESCRIPTION
Inspector:JEREMIAH VANDYKE-Comments:Signage stating"No frying,grilling,
} w, sauteing,or producing of grease laden vapors"made of durable construction with
z red back ground and white lettering installed in conspicous location near stove.
ce o = Example pic below.
cD Cr)C7 Z CQC
Z J
�•cu s-' w Location: Kitchen
,� OW � '
CL- co
FAIL 610.1.1 -Installation. Clothes dryer exhaust duct systems shall be installed in accordance with the
International Mechanical Code or the International Fuel Gas Code,and the
manufacturer's installation instructions.
Inspector:JEREMIAH VANDYKE-Comments:Clothes dryer vent tubing not installed
properly.Dryer venting into room.
Location:Clothes dryer
FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor
testing,and maintenance
Inspector:JEREMIAH VANDYKE-Comments:Fire Alarm report needs to be uploaded
to Compliance Engine by fire alarm contractor.
Location: Fire alarm panel
GENERAL NOTES
JEREMIAH VANDYKE-10/19/2023 @ 08:34 Fire drill completed 10/3/2023
JEREMIAH VANDYKE-10/19/2023 @ 08:48 01/28/2020 S-5 Year Sprinkler MIDWEST AUTOMATIC FIRE SPRINKLER COMPANY
Reviewed Compliant
JEREMIAH VANDYKE-10/19/2023 @ 08:50 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.*****Re inspection fees may be assessed for subsequent re-
inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent
re-inspections.-
JEREMIAH VANDYKE-10/19/2023 @ 08:34 Fire Extinguishers serviced by Superior December 2022.
Printed on 10/19/2023 @ 08:51
Page 2 of 3
GENERAL NOTES
JEREMIAH VANDYKE-10/19/2023 @ 08:47 Child care information.58 kids allowed.
JEREMIAH VANDYKE-10/19/2023 @ 08:47 01/18/2023 S-(Annual)Fire Sprinkler MIDWEST AUTOMATIC FIRE SPRINKLER COMPANY
Reviewed Compliant
JEREMIAH VANDYKE-10/19/2023 @ 08:49 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in
the event of an emergency at that address. Phone#319-291-2515.
JEREMIAH VANDYKE-10/19/2023 @ 08:50 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-
1615
JEREMIAH VANDYKE-10/19/2023 @ 08:50 Inspection Fee=$80.00
REINSPECTION DATE
11/18/2023
CONTACT SIGNATURE
Michelle Even Reason for not collecting a signature: NA
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on: 10/19/2023 @ 08:514A/
QUESTIONS ABOUT YOUR INSPECTION?
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
No phone number available
Printed on 10/19/2023 @ 08:51
Page 3 of 3