Loading...
HomeMy WebLinkAbout1955 HEALTH ST W 4 7 INVOICE DATE DUE DATE INVOICE# TOTAL DUE 11/16/2023 11/20/2023 2024-00000198 $80.00 0 45. AwIw W� S. 7VII Customer#: 24260 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable CEDAR VALLEY KIDS CHILDCARE 715 Mulberry St 1955 HEATH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 1955 HEATH ST- 10-17-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24260 11/16/2023 11/20/2023 2024-00000198 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE ZU0 ER& INSPECTION REPORT411K) UNITYPOINT ALUMNI HALL l CEDAR VALLEY IODS HILD '1955 HEATH ST BLDG 1955 HEATH ST,WATERLOO/A 50)03 Y DETAILS DD o° Inspection Date: 10/17/2023 ; Inspection Type:Annual Inspection(1Yr) 1 Inspection Numse+' 74 1 Shift: N/A 1 Unit: N/A Lead Inspector:JEREMIAH VANDYKE 1 Other Inspectors: N/A 1 Fee:$80.00 STATUS CODE DESCRIPTION FAIL 506.2-Key box maintenance. The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEREMIAH VANDYKE-Comments:Master key needed for knox box,will install on re inspect. Location: Not Provided FAIL 509.2-Equipment access. Approved access shall be provided and maintained for all fire protection system equipment to permit immediate safe operation and maintenance of such equipment. Storage,trash and other materials or objects shall not be placed or kept in such a manner that would prevent such equipment from being readily accessible. Inspector:JEREMIAH VANDYKE-Comments:Storage needs to be cleared around furnace and sprinkler riser by 36 inches. Discussed on site on what we needed. Location:Sprinkler riser room. FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:JEREMIAH VANDYKE-Comments:Open Junction electrical box needs covered. Location:Sprinkler riser room FAIL 606.3.3.2-Grease If during the inspection it is found that hoods,grease-removal devices,fans,ducts or accumulation. other appurtenances have an accumulation of grease,such components shall be cleaned in accordance with ANSI/IKECA C10. Printed on 10/19/2023 @ 08:51 Page 1 of 3 STATUS CODE DESCRIPTION Inspector:JEREMIAH VANDYKE-Comments:Signage stating"No frying,grilling, } w, sauteing,or producing of grease laden vapors"made of durable construction with z red back ground and white lettering installed in conspicous location near stove. ce o = Example pic below. cD Cr)C7 Z CQC Z J �•cu s-' w Location: Kitchen ,� OW � ' CL- co FAIL 610.1.1 -Installation. Clothes dryer exhaust duct systems shall be installed in accordance with the International Mechanical Code or the International Fuel Gas Code,and the manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Clothes dryer vent tubing not installed properly.Dryer venting into room. Location:Clothes dryer FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments:Fire Alarm report needs to be uploaded to Compliance Engine by fire alarm contractor. Location: Fire alarm panel GENERAL NOTES JEREMIAH VANDYKE-10/19/2023 @ 08:34 Fire drill completed 10/3/2023 JEREMIAH VANDYKE-10/19/2023 @ 08:48 01/28/2020 S-5 Year Sprinkler MIDWEST AUTOMATIC FIRE SPRINKLER COMPANY Reviewed Compliant JEREMIAH VANDYKE-10/19/2023 @ 08:50 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re- inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-10/19/2023 @ 08:34 Fire Extinguishers serviced by Superior December 2022. Printed on 10/19/2023 @ 08:51 Page 2 of 3 GENERAL NOTES JEREMIAH VANDYKE-10/19/2023 @ 08:47 Child care information.58 kids allowed. JEREMIAH VANDYKE-10/19/2023 @ 08:47 01/18/2023 S-(Annual)Fire Sprinkler MIDWEST AUTOMATIC FIRE SPRINKLER COMPANY Reviewed Compliant JEREMIAH VANDYKE-10/19/2023 @ 08:49 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-10/19/2023 @ 08:50 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883- 1615 JEREMIAH VANDYKE-10/19/2023 @ 08:50 Inspection Fee=$80.00 REINSPECTION DATE 11/18/2023 CONTACT SIGNATURE Michelle Even Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 10/19/2023 @ 08:514A/ QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 10/19/2023 @ 08:51 Page 3 of 3