Loading...
HomeMy WebLinkAbout1825 LA PORTE RD W 4' INVOICE DATE DUE DATE INVOICE# TOTAL DUE 11/16/2023 11/20/2023 2024-00000199 $100.00 C +lam ywiy.wl. y t.ti ►IwIY.1 *VS' Customer#: 24261 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BOARDERS INN AND SUITES 715 Mulberry St 1825 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1825 LA PORTE RD - 11-16-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24261 11/16/2023 11/20/2023 2024-00000199 $100.00 Less Prepayment $0.00 Total Due— $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. _ WATERLOO FIRE RESCUE 4: : INSPECTION REPORT BOARDERS INN&SUITES,1825 LA PORTE RD,BLDG 1825 LA PORTE RD, WATERLOO IA 50702 DETAILS Inspection Date: 11/16/2023 Inspection Type:Annual Inspection(1 Yr) Inspection Number:9503 Shift: N/A i Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1103.8-Single-and multiple- Single-and multiple-station smoke alarms shall be installed in existing Group I-1 and station smoke alarms. R occupancies in accordance with Sections 1103.8.1 through 1103.8.3. Inspector:JEREMIAH VANDYKE-Comments:Smoke alarms were either missing or not working. Location: Rooms 302,306,312,313,314,315,319, 121,205,209,212,215. FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:Egress light tested and failed. Location: East stairway on landing between 1st and 2nd floor. FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEREMIAH VANDYKE-Comments:Clothes Dryer Exhaust Duct system must be cleaned from the dryer to the outside DOCUMENTED by who and when serviced. Location:Guest and Hotels dryers Printed on 11/16/2023 @ 11:21 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments: 1 &2.Handful of rooms are under construction with missing sheetrock.3.3rd floor janitors laundry chute room scuddle hole to attic needs to be closed. Location: 1.Room#210.2.Hole in wall on 1st,2nd,and 3rd floor in hallway.3.3rd floor janitors laundry chute room. FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEREMIAH VANDYKE-Comments:Marked fire door not closing or latching properly. Location: East stairtower on 1st floor. FAIL 906.2-General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments:Fire extinguisher in elevator room is past due and needs to be serviced. Location: Elevator room on 1st floor. Printed on 11/16/2023 @ 11:21 Page 2 of 4 GENERAL NOTES JEREMIAH VANDYKE-11/16/2023 @ 11:20 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-11/16/2023 @ 11:21 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883- 1615 JEREMIAH VANDYKE-11/16/2023 @ 11:21 Inspection Fee=$100.00 JEREMIAH VANDYKE-11/16/2023 @ 11:06 03/02/2023 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-11/16/2023 @ 11:07 Fire extinguishers serviced/compliant by Superior Fire March 2023. JEREMIAH VANDYKE-11/16/2023 @ 11:20 1st floor rooms are under construction.And some rooms are being remodeled due to water leak. JEREMIAH VANDYKE-11/16/2023 @ 11:20 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re- inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- REINSPECTION DATE 12/16/2023 CONTACT SIGNATURE Chris Parrill Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE /)/// 2 gnedon: 11/16/2023@ 11:19 1�� Printed on 11/16/2023 @ 11:21 Page 3 of 4 QUESTIONS AEOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 11/16/2023 @ 1 1:21 Page 4 of 4