Loading...
HomeMy WebLinkAbout2011 LA PORTE RD aF W,q T INVOICE DATE DUE DATE INVOICE# TOTAL DUE � $100.00 12/06/2023 01/10/2024 2024-00000212 • i III • Ft"'Pr r tr O Customer#: 5002 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable COMFORT INN-WATERLOO 715 Mulberry St 2011 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL PROPERTY -2011 LA PORTE RD- 11-27-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5002 12/06/2023 01/10/2024 2024-00000212 $100.00 Less Prepayment $0.00 Total Due-* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE4.1gEntoo INSPECTION REPORT , COUNTRY INN&SUITES,4025 HAMMOND AVE,BLDG 4025 HAMMOND AVE,WATERLOO/A 50702 4410 DETAILS Inspection Date:11/17/2023 1 Inspection Type:Annual Inspection(1Yr) ( Inspection Number:9300 ! Shift: N/A j Station: N/A j Unit: N/A I Lead Inspector:JEREMIAH VANDYKE ! Other Inspectors: N/A I Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1103.8-Single-and multiple- Single-and multiple-station smoke alarms shall be installed in existing Group 1-1 and station smoke alarms. R occupancies in accordance with Sections 1103.8.1 through 1103.8.3. Inspector:JEREMIAH VANDYKE-Comments:Smoke alarm tested and failed. Location: Room 121. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments: Exit lights tested and failed OR broken OR faded. Location:1.Near room#329 floor exit.2.Near room#229 floor and ceiling exit light. FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEREMIAH VANDYKE-Comments:Storage near electrical panels need to be cleared by 36 inches.Tape is marked on the floor to maintain clearance. Location:2nd Floor electrical closet storage. Printed on 11/17/2023 @ 12:12 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 903.3.1 -Standards. Sprinkler systems shall be designed and installed in accordance with Section 903.3.1.1,unless otherwise permitted by Sections 903.3.1.2 and 903.3.1.3 and other chapters of this code,as applicable. Inspector:JEREMIAH VANDYKE-Comments:Contact Sprinkler contractor to have deficiencies corrected and contractor update Compliance Engine Website.Deficiency Found:Answer:five year items are due Deficiency Found:Answer: Heads in pool mechanical room and bathroom are showing signs of corrosion Deficiency Found: Answer: Head in entryway is painted Location: Not Provided GENERAL NOTES JEREMIAH VANDYKE-11/17/2023 @ 11:55 Fire Exinguishers serviced by Proshield Jan 2023. JEREMIAH VANDYKE-11/17/2023 @ 11:56 11/14/2023 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-11/17/2023 @ 11:56 10/23/2023 S-(Annual)Fire Sprinkler BLACKHAWK AUTOMATIC SPRINKLERS, INC. Reviewed Deficient JEREMIAH VANDYKE-11/17/2023 @ 12:10 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. JEREMIAH VANDYKE-11/17/2023 @ 12:11 Inspection Fee=$100.00 JEREMIAH VANDYKE-11/17/2023 @ 12:11 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re- inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-11/17/2023 @ 12:11 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883- 1615 REINSPECTION DATE 12/17/2023 Printed on 11/17/2023 @ 12:12 Page 2 of 3 CONTACT SIGNATURE Mindy Jones Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE , / Signed on: 11/17/2023 @ 12:10 V 74— QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 11/17/2023 @ 12:12 Page 3of3