HomeMy WebLinkAbout322 WASHINGTON ST DF W t4% INVOICE DATE DUE DATE INVOICE# TOTAL DUE
12/06/2023 01/10/2024 2024-00000219 $80.00
i� f f V,-hy„,,,,f�ffrififffffff, o
• v ltti� f.[.a"r .tar •
y = � C?
•..r...ws 4
sS
V17R
Customer#: 21386 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
SNOWDEN HOUSE 715 Mulberry St
306 WASHINGTON WATERLOO, IA 50703
WATERLOO,IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL PROPERTY-322 WASHINGTON ST- 11-28-23 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
21386 12/06/2023 01/10/2024 2024-00000219 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
A
WATERLOO FIRE RESCUE 4P1ERto.
INSPECTION REPORT -
SNOWDEN HOUSE,322 WASHINGTON ST,BLDG 322 WASHINGTON ST,WATERLOO/A S0702 f
01:\ 42ZUOI
DETAILS
Inspection Date: 11/28/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:7080 I Shift: N/A I Station: N/A
Unit: N/A ! Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided
clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000
volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000
volts.The minimum required working space shall be not less than 30 inches(762 mm)
in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be
providedin front of electrical service equipment.Where the electrical service
equipment is wider than 30 inches(762 mm),the minimum working space shall be
not less than the width of the equipment.Storage of materials shall not be located
within the designated working space. Exceptions: 1.Where other dimensions are
required or allowed by NFPA 70.2.Access openings into attics or under-floor areas
that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments:remove obstructions. Maintain a minimum of 36"
clearance to electrical panels at all times.Install permanent sign stating"No Storage
Maintain 36"Clearance".Laminated paper not accepted.
Location:upstairs side stage
GENERAL NOTES
JEFF SIEBEL-11/28/2023 @ 12:59 annual inspection$80
REINSPECTION DATE
12/15/2023
CONTACT SIGNATURE
Al Sweeney (� /
Signed on: 11/28/2023 @ 13:00 `- �.��-/
Y`
Printed on 11/28/2023 @ 13:03
Page 1 of 2
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:11/28/2023 @ 13:00 trj.
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 1 1/28/2023 @ 13:03
Page 2 of 2